Thanks for the information you've researched and published.

I see your comments about the possible use of some commands .. the following information comes from page 3 of the manual for an ADP-12 XGT tool management adapter, which may give some insight into some of these command/responses?:

Anti-theft setting

You can set the PIN code for each tool and battery cartridge.
The default PIN code of all tools and battery cartridges are "0000".
By setting PIN code other than "0000", two anti-theft solutions below can be available.

Product / battery matching

Only the combination of the tool and the battery cartridge with the same PINs can be operated.
If you use the tool and the battery cartridge with different PINs, the tool does not operate and all indicator lamps of
the battery cartridge blink.

Battery timer setting

An expiration time / date can be set to battery cartridges according to a construction schedule. The battery cartridges
are not usable after the timer is expired.

Tool checker

You can confirm the operation history of the tool. Confirming those could be utilized for the future work.

Battery checker

You can confirm the usage history and the diagnosis result of the battery cartridge.

Notepad registration

You can take a note about product management, maintenance history, etc.

Stand-alone mode

This is the useful way to register the same setting to multiple tools or battery cartridges.
In the stand-alone mode, by registering the settings in the connector in advance, you can register the settings in the
tool or battery just by installing tool or battery to the connector.

NOTE: "Communication (Comm) Mode" is selected by factory default.
NOTE: In the "Communication (Comm) Mode", register the settings of the product or battery by communicating