Issue overview
The screenshot below shows the inlet and outlet flow rates and temperatures of the air and water across a chilled water cooling coil. From 24:00 to 5:00, there is no air flow across the coil and no change in air temperature from the inlet and outlet, yet there is chilled water flow through the coil with a temperature increase of 3-4C. Even with water flow through the coil, there shouldn't be an increase in chilled water temperature through the coil if there is no air flow. The Cooling Coil Total Cooling Energy output does report 0 energy consumption during this period.