Skip to content

HeatPump:PlantLoop:EIR:* allows simultaneous heating/cooling with just a warning #8782

@matthew-larson

Description

@matthew-larson

Issue overview

When using the HeatPump:PlantLoop:EIR:* objects with companion coils, there is nothing to prevent the heating/cooling heat pumps from operating simultaneously, only a warning is produced at the end of the error file. Since this can cause significant error in the modeling with simultaneous heating/cooling, I propose either a fatal error with more description to assist the user in understanding why the heat pumps are running simultaneously or implement a fix where it only allows the heating/cooling heat pump with the greater load to run while shutting off it's companion coil. Below is a screenshot of the current function that produces the warning and the actual warning produced.

image

image

Details

Some additional details for this issue (if relevant):

  • EnergyPlus v9.5

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

  • Defect file added (list location of defect file here)
  • Ticket added to Pivotal for defect (development team task)
  • Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)

Metadata

Metadata

Labels

DefectIncludes code to repair a defect in EnergyPlusNotIDDChangeCode does not impact IDD (can be merged after IO freeze)

Type

No type

Projects

No projects

Relationships

None yet

Development

No branches or pull requests