diff --git a/doc/input-output-reference/src/overview/group-air-distribution-equipment.tex b/doc/input-output-reference/src/overview/group-air-distribution-equipment.tex index 8c6d202575a..568ebcb784b 100644 --- a/doc/input-output-reference/src/overview/group-air-distribution-equipment.tex +++ b/doc/input-output-reference/src/overview/group-air-distribution-equipment.tex @@ -924,10 +924,6 @@ \subsubsection{Inputs}\label{inputs-7-000} The name of the HVAC system node to which the unit sends its outlet air. This should be one of the inlet air nodes of the zone which is being served. -\paragraph{Field: Reheat Coil Air Inlet Node Name}\label{field-reheat-coil-air-inlet-node-name} - -The name of the HVAC system node which is the inlet node of the unit's heating coil. This is also the outlet node of the unit's fan. - \paragraph{Field: Zone Mixer Name}\label{field-zone-mixer-name} The name of a zone mixer component (object: \hyperref[airloophvaczonemixer]{AirLoopHVAC:ZoneMixer}) which composes part of the unit. Note that some of the input for the mixer will duplicate input fields of the powered induction unit. One of the zone mixer inlet nodes should be the same as the supply air inlet node of the PIU; the other inlet node of the zone mixer should be the same as the secondary air inlet node of the PIU. The outlet node of the zone mixer should be the same as the inlet node of the PIU fan. @@ -1186,10 +1182,6 @@ \subsubsection{Inputs}\label{inputs-8-000} The name of the HVAC system node to which the unit sends its outlet air. This should be one of the inlet air nodes of the zone which is being served. -\paragraph{Field: Reheat Coil Air Inlet Node Name}\label{field-reheat-coil-air-inlet-node-name-1} - -The name of the HVAC system node which is the inlet node of the unit's heating coil. This is also the outlet node of the unit's zone mixer. - \paragraph{Field: Zone Mixer Name}\label{field-zone-mixer-name-1} The name of an zone mixer component (object: \hyperref[airloophvaczonemixer]{AirLoopHVAC:ZoneMixer}) which composes part of the unit. Note that some of the input for the mixer will duplicate input fields of the powered induction unit. One of the zone mixer inlet nodes should be the same as the supply air inlet node of the PIU; the other inlet node of the zone mixer should be the same as the air outlet node of the fan. The outlet node of the zone mixer should be the same as the inlet node of the heating coil. diff --git a/idd/Energy+.idd.in b/idd/Energy+.idd.in index 741cd29a8ea..7c5c0235034 100644 --- a/idd/Energy+.idd.in +++ b/idd/Energy+.idd.in @@ -48803,24 +48803,22 @@ AirTerminal:SingleDuct:SeriesPIU:Reheat, \type node A5, \field Outlet Node Name \type node - A6, \field Reheat Coil Air Inlet Node Name - \type node - A7, \field Zone Mixer Name + A6, \field Zone Mixer Name \type object-list \object-list ZoneMixers - A8, \field Fan Name + A7, \field Fan Name \note Fan type must be Fan:SystemModel or Fan:ConstantVolume \type object-list \object-list FansCV \object-list FansSystemModel - A9, \field Reheat Coil Object Type + A8, \field Reheat Coil Object Type \required-field \type choice \key Coil:Heating:Water \key Coil:Heating:Electric \key Coil:Heating:Fuel \key Coil:Heating:Steam - A10, \field Reheat Coil Name + A9, \field Reheat Coil Name \required-field \type object-list \object-list HeatingCoilName @@ -48841,7 +48839,7 @@ AirTerminal:SingleDuct:SeriesPIU:Reheat, \type real \minimum> 0.0 \default 0.001 - A11, \field Fan Control Type + A10, \field Fan Control Type \note If VariableSpeed, then the fan object type must be Fan:SystemModel \type choice \key VariableSpeed @@ -48854,7 +48852,7 @@ AirTerminal:SingleDuct:SeriesPIU:Reheat, \minimum 0.0 \maximum 1.0 \default 0.3 - A12, \field Heating Control Type + A11, \field Heating Control Type \type choice \key Staged \key Modulated @@ -48916,25 +48914,22 @@ AirTerminal:SingleDuct:ParallelPIU:Reheat, \type node A5, \field Outlet Node Name \type node - A6, \field Reheat Coil Air Inlet Node Name - \type node - \note mixer outlet node - A7, \field Zone Mixer Name + A6, \field Zone Mixer Name \type object-list \object-list ZoneMixers - A8, \field Fan Name + A7, \field Fan Name \note Fan type must be Fan:SystemModel or Fan:ConstantVolume \type object-list \object-list FansCV \object-list FansSystemModel - A9, \field Reheat Coil Object Type + A8, \field Reheat Coil Object Type \required-field \type choice \key Coil:Heating:Water \key Coil:Heating:Electric \key Coil:Heating:Fuel \key Coil:Heating:Steam - A10, \field Reheat Coil Name + A9, \field Reheat Coil Name \required-field \type object-list \object-list HeatingCoilName @@ -48955,7 +48950,7 @@ AirTerminal:SingleDuct:ParallelPIU:Reheat, \type real \minimum> 0.0 \default 0.001 - A11, \field Fan Control Type + A10, \field Fan Control Type \note If VariableSpeed, then the fan object type must be Fan:SystemModel \type choice \key VariableSpeed @@ -48968,7 +48963,7 @@ AirTerminal:SingleDuct:ParallelPIU:Reheat, \minimum 0.0 \maximum 1.0 \default 0.3 - A12, \field Heating Control Type + A11, \field Heating Control Type \type choice \key Staged \key Modulated diff --git a/src/EnergyPlus/PoweredInductionUnits.cc b/src/EnergyPlus/PoweredInductionUnits.cc index a42545479e5..432bb6da86f 100644 --- a/src/EnergyPlus/PoweredInductionUnits.cc +++ b/src/EnergyPlus/PoweredInductionUnits.cc @@ -381,29 +381,47 @@ void GetPIUs(EnergyPlusData &state) ObjectIsParent, "Outlet Node Name"); - thisPIU.HCoilInAirNode = GetOnlySingleNode(state, - ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_air_inlet_node_name"), - ErrorsFound, - connectionType, - thisPIU.Name, - DataLoopNode::NodeFluidType::Air, - DataLoopNode::ConnectionType::Internal, - NodeInputManager::CompFluidStream::Primary, - ObjectIsParent, - "Reheat Coil Air Inlet Node Name"); - // The reheat coil control node is necessary for hot water reheat, but not necessary for - // electric or gas reheat. - if (thisPIU.HCoilType == HtgCoilType::SimpleHeating) { + // The reheat coil control node is necessary for hot water reheat, but not necessary for electric or gas reheat. + switch (thisPIU.HCoilType) { + case HtgCoilType::SimpleHeating: { + thisPIU.HCoilInAirNode = + WaterCoils::GetCoilInletNode(state, + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), + ErrorsFound); + thisPIU.HotControlNode = GetCoilWaterInletNode(state, ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), ErrorsFound); + break; } - if (thisPIU.HCoilType == HtgCoilType::SteamAirHeating) { + case HtgCoilType::SteamAirHeating: { + int SteamCoilIndex = SteamCoils::GetSteamCoilIndex(state, + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), + ErrorsFound); + thisPIU.HCoilInAirNode = SteamCoils::GetCoilAirInletNode( + state, SteamCoilIndex, ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), ErrorsFound); + thisPIU.HotControlNode = GetCoilSteamInletNode(state, ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), ErrorsFound); + break; + } + case HtgCoilType::Electric: + case HtgCoilType::Gas: { + thisPIU.HCoilInAirNode = + HeatingCoils::GetCoilInletNode(state, + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), + ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), + ErrorsFound); + break; + } + default: { + break; + } } thisPIU.MixerName = ip->getAlphaFieldValue(fields, objectSchemaProps, "zone_mixer_name"); thisPIU.FanName = ip->getAlphaFieldValue(fields, objectSchemaProps, "fan_name"); @@ -474,7 +492,7 @@ void GetPIUs(EnergyPlusData &state) "UNDEFINED", thisPIU.FanName, "UNDEFINED", - ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_air_inlet_node_name")); + state.dataLoopNodes->NodeID(thisPIU.HCoilInAirNode)); } else if (cCurrentModuleObject == "AirTerminal:SingleDuct:ParallelPIU:Reheat") { SetUpCompSets(state, thisPIU.UnitType, @@ -491,7 +509,7 @@ void GetPIUs(EnergyPlusData &state) thisPIU.Name, ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_object_type"), ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_name"), - ip->getAlphaFieldValue(fields, objectSchemaProps, "reheat_coil_air_inlet_node_name"), + state.dataLoopNodes->NodeID(thisPIU.HCoilInAirNode), ip->getAlphaFieldValue(fields, objectSchemaProps, "outlet_node_name")); // Register component set data diff --git a/src/ExpandObjects/epfilter.f90 b/src/ExpandObjects/epfilter.f90 index 24f0e87d1b3..f6572f90b78 100644 --- a/src/ExpandObjects/epfilter.f90 +++ b/src/ExpandObjects/epfilter.f90 @@ -9589,7 +9589,6 @@ SUBROUTINE CreateNewVAV END IF CALL AddToObjFld('Secondary Air Inlet Node Name', base + fpvzNameOff,' PIU Secondary Inlet') CALL AddToObjFld('Outlet Node Name', base + fpvzNameOff,' Supply Inlet') - CALL AddToObjFld('Reheat Coil Air Inlet Node Name', base + fpvzNameOff,' PIU Fan Outlet') CALL AddToObjFld('Zone Mixer Name', base + fpvzNameOff,' PIU Mixer') CALL AddToObjFld('Fan Name', base + fpvzNameOff,' PIU Fan') IF (reheatCoilType .EQ. ctHotWater) THEN @@ -9627,7 +9626,6 @@ SUBROUTINE CreateNewVAV END IF CALL AddToObjFld('Secondary Air Inlet Node Name', base + fpvzNameOff,' PIU Secondary Inlet') CALL AddToObjFld('Outlet Node Name', base + fpvzNameOff,' Supply Inlet') - CALL AddToObjFld('Reheat Coil Air Inlet Node Name', base + fpvzNameOff,' PIU Mixer Outlet') CALL AddToObjFld('Zone Mixer Name', base + fpvzNameOff,' PIU Mixer') CALL AddToObjFld('Fan Name', base + fpvzNameOff,' PIU Fan') IF (reheatCoilType .EQ. ctHotWater) THEN diff --git a/src/Transition/CreateNewIDFUsingRulesV26_1_0.f90 b/src/Transition/CreateNewIDFUsingRulesV26_1_0.f90 index 3343f555284..803ab17a30d 100644 --- a/src/Transition/CreateNewIDFUsingRulesV26_1_0.f90 +++ b/src/Transition/CreateNewIDFUsingRulesV26_1_0.f90 @@ -383,6 +383,21 @@ SUBROUTINE CreateNewIDFUsingRules(EndOfFile,DiffOnly,InLfn,AskForInput,InputFile ! If your original object starts with A, insert the rules here + CASE('AIRTERMINAL:SINGLEDUCT:PARALLELPIU:REHEAT') + CALL GetNewObjectDefInIDD(ObjectName,NwNumArgs,NwAorN,NwReqFld,NwObjMinFlds,NwFldNames,NwFldDefaults,NwFldUnits) + nodiff=.false. + OutArgs(1:9)=InArgs(1:9) + ! InArgs(10) is deleted + OutArgs(10:CurArgs-1)=InArgs(11:CurArgs) + CurArgs = CurArgs - 1 + CASE('AIRTERMINAL:SINGLEDUCT:SERIESPIU:REHEAT') + CALL GetNewObjectDefInIDD(ObjectName,NwNumArgs,NwAorN,NwReqFld,NwObjMinFlds,NwFldNames,NwFldDefaults,NwFldUnits) + nodiff=.false. + OutArgs(1:8)=InArgs(1:8) + ! InArgs(9) is deleted + OutArgs(9:CurArgs-1)=InArgs(10:CurArgs) + CurArgs = CurArgs - 1 + ! If your original object starts with C, insert the rules here ! If your original object starts with D, insert the rules here diff --git a/src/Transition/InputRulesFiles/Rules25-2-0-to-26-1-0.md b/src/Transition/InputRulesFiles/Rules25-2-0-to-26-1-0.md index 3f77dc6cdbc..b8f45ce1622 100644 --- a/src/Transition/InputRulesFiles/Rules25-2-0-to-26-1-0.md +++ b/src/Transition/InputRulesFiles/Rules25-2-0-to-26-1-0.md @@ -12,6 +12,14 @@ The alpha/numeric A/N numbers are not as important here. # Object Change: ObjectStartsWithA +# Object Change: AirTerminal:SingleDuct:ParallelPIU:Reheat +# Object Change: AirTerminal:SingleDuct:SeriesPIU:Reheat + +Remove field A6 "Reheat Coil Air Inlet Node Name" +Shift remaining alpha fields down 1 (i.e. A7-A12 now A6-A11) + +See pull request [#11366](https://github.com/NREL/EnergyPlus/pull/11366) + # Object Change: ObjectStartsWithB # Object Change: ObjectStartsWithC diff --git a/testfiles/5ZoneAirCooledConvCoef.idf b/testfiles/5ZoneAirCooledConvCoef.idf index 54a3850abf0..cba46313733 100644 --- a/testfiles/5ZoneAirCooledConvCoef.idf +++ b/testfiles/5ZoneAirCooledConvCoef.idf @@ -2426,7 +2426,6 @@ SPACE1-1 ATU In Node, !- Supply Air Inlet Node Name SPACE1-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE1-1 In Node, !- Outlet Node Name - SPACE1-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2479,7 +2478,6 @@ SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE2-1 In Node, !- Outlet Node Name - SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2531,7 +2529,6 @@ SPACE3-1 ATU In Node, !- Supply Air Inlet Node Name SPACE3-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE3-1 In Node, !- Outlet Node Name - SPACE3-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2584,7 +2581,6 @@ SPACE4-1 ATU In Node, !- Supply Air Inlet Node Name SPACE4-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE4-1 In Node, !- Outlet Node Name - SPACE4-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/5ZoneAirCooledConvCoef_VSFan.idf b/testfiles/5ZoneAirCooledConvCoef_VSFan.idf index a69cf058914..01e62a5be76 100644 --- a/testfiles/5ZoneAirCooledConvCoef_VSFan.idf +++ b/testfiles/5ZoneAirCooledConvCoef_VSFan.idf @@ -2426,7 +2426,6 @@ SPACE1-1 ATU In Node, !- Supply Air Inlet Node Name SPACE1-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE1-1 In Node, !- Outlet Node Name - SPACE1-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2502,7 +2501,6 @@ SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE2-1 In Node, !- Outlet Node Name - SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2566,7 +2564,6 @@ SPACE3-1 ATU In Node, !- Supply Air Inlet Node Name SPACE3-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE3-1 In Node, !- Outlet Node Name - SPACE3-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2631,7 +2628,6 @@ SPACE4-1 ATU In Node, !- Supply Air Inlet Node Name SPACE4-1 ATU Sec Node, !- Secondary Air Inlet Node Name SPACE4-1 In Node, !- Outlet Node Name - SPACE4-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MaxZd.idf b/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MaxZd.idf index eee866998a4..e5fd919e353 100644 --- a/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MaxZd.idf +++ b/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MaxZd.idf @@ -1483,7 +1483,6 @@ ZN_1_FLR_1_SEC_1 VAV Box Inlet Node, !- Supply Air Inlet Node Name ZN_1_FLR_1_SEC_1 Exhaust Node, !- Secondary Air Inlet Node Name ZN_1_FLR_1_SEC_1 VAV Box Outlet Node, !- Outlet Node Name - ZN_1_FLR_1_SEC_1 VAV Box Damper Node, !- Reheat Coil Air Inlet Node Name Zone 1 PIU Mixer, !- Zone Mixer Name Zone 1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MultiPath.idf b/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MultiPath.idf index 24588533f5d..88f960d3551 100644 --- a/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MultiPath.idf +++ b/testfiles/5ZoneVAV-ChilledWaterStorage-Mixed_DCV_MultiPath.idf @@ -1492,7 +1492,6 @@ ZN_1_FLR_1_SEC_1 VAV Box Inlet Node, !- Supply Air Inlet Node Name ZN_1_FLR_1_SEC_1 Exhaust Node, !- Secondary Air Inlet Node Name ZN_1_FLR_1_SEC_1 VAV Box Outlet Node, !- Outlet Node Name - ZN_1_FLR_1_SEC_1 VAV Box Damper Node, !- Reheat Coil Air Inlet Node Name Zone 1 PIU Mixer, !- Zone Mixer Name Zone 1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/5ZoneVAV-Pri-SecLoop.idf b/testfiles/5ZoneVAV-Pri-SecLoop.idf index 86e84b842bc..72b2f97e087 100644 --- a/testfiles/5ZoneVAV-Pri-SecLoop.idf +++ b/testfiles/5ZoneVAV-Pri-SecLoop.idf @@ -2034,7 +2034,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2168,7 +2167,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2302,7 +2300,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2436,7 +2433,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/5ZoneVAV-Pri-SecLoop_csv.idf b/testfiles/5ZoneVAV-Pri-SecLoop_csv.idf index 854dcf7414d..a73a0deb480 100644 --- a/testfiles/5ZoneVAV-Pri-SecLoop_csv.idf +++ b/testfiles/5ZoneVAV-Pri-SecLoop_csv.idf @@ -2039,7 +2039,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2173,7 +2172,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2307,7 +2305,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2441,7 +2438,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/IceStorage-Parallel.idf b/testfiles/IceStorage-Parallel.idf index ec99f783ebd..c6624747100 100644 --- a/testfiles/IceStorage-Parallel.idf +++ b/testfiles/IceStorage-Parallel.idf @@ -2045,7 +2045,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2179,7 +2178,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2313,7 +2311,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2447,7 +2444,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/IceStorage-Series-ChillerDownstream.idf b/testfiles/IceStorage-Series-ChillerDownstream.idf index 0232cd59b32..4cb3b081744 100644 --- a/testfiles/IceStorage-Series-ChillerDownstream.idf +++ b/testfiles/IceStorage-Series-ChillerDownstream.idf @@ -2043,7 +2043,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2177,7 +2176,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2311,7 +2309,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2445,7 +2442,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/IceStorage-Series-ChillerUpstream.idf b/testfiles/IceStorage-Series-ChillerUpstream.idf index c08220104ec..ab3de357135 100644 --- a/testfiles/IceStorage-Series-ChillerUpstream.idf +++ b/testfiles/IceStorage-Series-ChillerUpstream.idf @@ -2043,7 +2043,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2177,7 +2176,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2311,7 +2309,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2445,7 +2442,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/PIUAuto.idf b/testfiles/PIUAuto.idf index 226a3c6da92..0985e6ca196 100644 --- a/testfiles/PIUAuto.idf +++ b/testfiles/PIUAuto.idf @@ -2306,7 +2306,6 @@ Zone 1 PIU Pri Air Inlet Node, !- Supply Air Inlet Node Name Zone 1 PIU Sec Air Inlet Node, !- Secondary Air Inlet Node Name Zone 1 PIU Air Outlet Node, !- Outlet Node Name - Zone 1 Reheat Air Inlet Node, !- Reheat Coil Air Inlet Node Name Zone 1 PIU Mixer, !- Zone Mixer Name Zone 1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2345,7 +2344,6 @@ Zone 3 PIU Pri Air Inlet Node, !- Supply Air Inlet Node Name Zone 3 PIU Sec Air Inlet Node, !- Secondary Air Inlet Node Name Zone 3 PIU Air Outlet Node, !- Outlet Node Name - Zone 3 Reheat Air Inlet Node, !- Reheat Coil Air Inlet Node Name Zone 3 PIU Mixer, !- Zone Mixer Name Zone 3 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/PlantLoopHeatPump_EIR_Large-Office-2-AWHP-DedHR-AuxBoiler-Pri-Sec-HW.idf b/testfiles/PlantLoopHeatPump_EIR_Large-Office-2-AWHP-DedHR-AuxBoiler-Pri-Sec-HW.idf index bc8de03fe35..70c7f764056 100644 --- a/testfiles/PlantLoopHeatPump_EIR_Large-Office-2-AWHP-DedHR-AuxBoiler-Pri-Sec-HW.idf +++ b/testfiles/PlantLoopHeatPump_EIR_Large-Office-2-AWHP-DedHR-AuxBoiler-Pri-Sec-HW.idf @@ -4861,7 +4861,6 @@ Core_bottom PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Core_bottom PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Core_bottom PIUHEATING Outlet Node Name, !- Outlet Node Name - Core_bottom PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Core_bottom PIUHEATING Mixer, !- Zone Mixer Name Core_bottom PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5003,7 +5002,6 @@ Core_mid PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Core_mid PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Core_mid PIUHEATING Outlet Node Name, !- Outlet Node Name - Core_mid PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Core_mid PIUHEATING Mixer, !- Zone Mixer Name Core_mid PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5132,7 +5130,6 @@ Core_top PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Core_top PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Core_top PIUHEATING Outlet Node Name, !- Outlet Node Name - Core_top PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Core_top PIUHEATING Mixer, !- Zone Mixer Name Core_top PIUHEATING Fan, !- Fan Name Coil:Heating:Electric, !- Reheat Coil Object Type @@ -5252,7 +5249,6 @@ Perimeter_bot_ZN_1 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_bot_ZN_1 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_bot_ZN_1 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_bot_ZN_1 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_bot_ZN_1 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_bot_ZN_1 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5381,7 +5377,6 @@ Perimeter_bot_ZN_2 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_bot_ZN_2 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_bot_ZN_2 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_bot_ZN_2 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_bot_ZN_2 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_bot_ZN_2 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5510,7 +5505,6 @@ Perimeter_bot_ZN_3 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_bot_ZN_3 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_bot_ZN_3 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_bot_ZN_3 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_bot_ZN_3 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_bot_ZN_3 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5639,7 +5633,6 @@ Perimeter_bot_ZN_4 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_bot_ZN_4 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_bot_ZN_4 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_bot_ZN_4 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_bot_ZN_4 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_bot_ZN_4 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5768,7 +5761,6 @@ Perimeter_mid_ZN_1 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_mid_ZN_1 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_mid_ZN_1 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_mid_ZN_1 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_mid_ZN_1 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_mid_ZN_1 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -5897,7 +5889,6 @@ Perimeter_mid_ZN_2 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_mid_ZN_2 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_mid_ZN_2 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_mid_ZN_2 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_mid_ZN_2 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_mid_ZN_2 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6026,7 +6017,6 @@ Perimeter_mid_ZN_3 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_mid_ZN_3 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_mid_ZN_3 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_mid_ZN_3 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_mid_ZN_3 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_mid_ZN_3 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6155,7 +6145,6 @@ Perimeter_mid_ZN_4 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_mid_ZN_4 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_mid_ZN_4 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_mid_ZN_4 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_mid_ZN_4 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_mid_ZN_4 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6284,7 +6273,6 @@ Perimeter_top_ZN_1 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_top_ZN_1 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_top_ZN_1 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_top_ZN_1 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_top_ZN_1 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_top_ZN_1 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6413,7 +6401,6 @@ Perimeter_top_ZN_2 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_top_ZN_2 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_top_ZN_2 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_top_ZN_2 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_top_ZN_2 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_top_ZN_2 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6542,7 +6529,6 @@ Perimeter_top_ZN_3 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_top_ZN_3 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_top_ZN_3 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_top_ZN_3 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_top_ZN_3 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_top_ZN_3 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -6671,7 +6657,6 @@ Perimeter_top_ZN_4 PIUHEATING Primary Inlet Node Name, !- Supply Air Inlet Node Name Perimeter_top_ZN_4 PIUHEATING Secondary Inlet Node, !- Secondary Air Inlet Node Name Perimeter_top_ZN_4 PIUHEATING Outlet Node Name, !- Outlet Node Name - Perimeter_top_ZN_4 PIUHEATING Reheat Coil Air In Node, !- Reheat Coil Air Inlet Node Name Perimeter_top_ZN_4 PIUHEATING Mixer, !- Zone Mixer Name Perimeter_top_ZN_4 PIUHEATING Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/Standard621SimplifiedProcedure_PIUterminal.idf b/testfiles/Standard621SimplifiedProcedure_PIUterminal.idf index a11ea5b83c0..b0098cf5f47 100644 --- a/testfiles/Standard621SimplifiedProcedure_PIUterminal.idf +++ b/testfiles/Standard621SimplifiedProcedure_PIUterminal.idf @@ -2279,7 +2279,6 @@ Zone 1 PIU Pri Air Inlet Node, !- Supply Air Inlet Node Name Zone 1 PIU Sec Air Inlet Node, !- Secondary Air Inlet Node Name Zone 1 PIU Air Outlet Node, !- Outlet Node Name - Zone 1 Reheat Air Inlet Node, !- Reheat Coil Air Inlet Node Name Zone 1 PIU Mixer, !- Zone Mixer Name Zone 1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2318,7 +2317,6 @@ Zone 3 PIU Pri Air Inlet Node, !- Supply Air Inlet Node Name Zone 3 PIU Sec Air Inlet Node, !- Secondary Air Inlet Node Name Zone 3 PIU Air Outlet Node, !- Outlet Node Name - Zone 3 Reheat Air Inlet Node, !- Reheat Coil Air Inlet Node Name Zone 3 PIU Mixer, !- Zone Mixer Name Zone 3 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/testfiles/TwoWayCommonPipe_Pri-Sec.idf b/testfiles/TwoWayCommonPipe_Pri-Sec.idf index d0291f1768b..349ce6d6b99 100644 --- a/testfiles/TwoWayCommonPipe_Pri-Sec.idf +++ b/testfiles/TwoWayCommonPipe_Pri-Sec.idf @@ -2026,7 +2026,6 @@ SPACE1-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE1-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE1-1 Supply Inlet, !- Outlet Node Name - SPACE1-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE1-1 PIU Mixer, !- Zone Mixer Name SPACE1-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2160,7 +2159,6 @@ SPACE2-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE2-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE2-1 Supply Inlet, !- Outlet Node Name - SPACE2-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE2-1 PIU Mixer, !- Zone Mixer Name SPACE2-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2294,7 +2292,6 @@ SPACE3-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE3-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE3-1 Supply Inlet, !- Outlet Node Name - SPACE3-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE3-1 PIU Mixer, !- Zone Mixer Name SPACE3-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type @@ -2428,7 +2425,6 @@ SPACE4-1 Zone Equip Inlet, !- Supply Air Inlet Node Name SPACE4-1 PIU Secondary From Zone, !- Secondary Air Inlet Node Name SPACE4-1 Supply Inlet, !- Outlet Node Name - SPACE4-1 PIU Fan Outlet, !- Reheat Coil Air Inlet Node Name SPACE4-1 PIU Mixer, !- Zone Mixer Name SPACE4-1 PIU Fan, !- Fan Name Coil:Heating:Water, !- Reheat Coil Object Type diff --git a/tst/EnergyPlus/unit/AirTerminalSingleDuctPIUReheat.unit.cc b/tst/EnergyPlus/unit/AirTerminalSingleDuctPIUReheat.unit.cc index 86898202662..35c3e561d91 100644 --- a/tst/EnergyPlus/unit/AirTerminalSingleDuctPIUReheat.unit.cc +++ b/tst/EnergyPlus/unit/AirTerminalSingleDuctPIUReheat.unit.cc @@ -87,7 +87,6 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctSeriesPIUReheat_GetInputtest) " SPACE1-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE1-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE1-1 In Node, !- Outlet Node Name", - " SPACE1-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE1-1 PIU Mixer, !- Zone Mixer Name", " SPACE1-1 PIU Fan, !- Fan Name", " Coil:Heating:Water, !- Reheat Coil Object Type", @@ -209,7 +208,6 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctSeriesPIU_SetADUInletNodeTest) " SPACE1-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE1-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE1-1 In Node, !- Outlet Node Name", - " SPACE1-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE1-1 PIU Mixer, !- Zone Mixer Name", " SPACE1-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -1077,7 +1075,6 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctSeriesPIU_SimTest) " Node 24, !- Supply Air Inlet Node Name", " Node 25, !- Secondary Air Inlet Node Name", " Node 6, !- Outlet Node Name", - " Series PIU Elec Rht Fan Outlet, !- Reheat Coil Air Inlet Node Name", " Series PIU Elec Rht Mixer, !- Zone Mixer Name", " Series PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", diff --git a/tst/EnergyPlus/unit/OccupantDiversity.unit.cc b/tst/EnergyPlus/unit/OccupantDiversity.unit.cc index b7aca63e5d9..7e886784889 100644 --- a/tst/EnergyPlus/unit/OccupantDiversity.unit.cc +++ b/tst/EnergyPlus/unit/OccupantDiversity.unit.cc @@ -969,7 +969,6 @@ TEST_F(EnergyPlusFixture, OccupantDiversityManualTest) " Space ATU In Node, !- Supply Air Inlet Node Name", " Space Sec In Node, !- Secondary Air Inlet Node Name", " Space In Node, !- Outlet Node Name", - " PIU Reheat Air Inlet Node, !-Reheat Coil Air Inlet Node Name", " PIU Zone Mixer, !-Zone Mixer Name", " PIU Fan, !-Fan Name", " Coil:Heating:Fuel, !-Reheat Coil Object Type", @@ -1982,7 +1981,6 @@ TEST_F(EnergyPlusFixture, OccupantDiversityAutoSizeTest) " Space ATU In Node, !- Supply Air Inlet Node Name", " Space Sec In Node, !- Secondary Air Inlet Node Name", " Space In Node, !- Outlet Node Name", - " PIU Reheat Air Inlet Node, !-Reheat Coil Air Inlet Node Name", " PIU Zone Mixer, !-Zone Mixer Name", " PIU Fan, !-Fan Name", " Coil:Heating:Fuel, !-Reheat Coil Object Type", diff --git a/tst/EnergyPlus/unit/PoweredInductionUnits.unit.cc b/tst/EnergyPlus/unit/PoweredInductionUnits.unit.cc index 1987ceb0400..87ebdd535be 100644 --- a/tst/EnergyPlus/unit/PoweredInductionUnits.unit.cc +++ b/tst/EnergyPlus/unit/PoweredInductionUnits.unit.cc @@ -122,7 +122,6 @@ TEST_F(EnergyPlusFixture, ParallelPIUTest1) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -354,7 +353,6 @@ TEST_F(EnergyPlusFixture, SeriesPIUTest1) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -644,7 +642,6 @@ TEST_F(EnergyPlusFixture, SeriesPIUZoneOAVolumeFlowRateTest) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -1254,7 +1251,6 @@ TEST_F(EnergyPlusFixture, PIU_InducedAir_Plenums) " SeriesPIU Supply Air Inlet Node, !- Supply Air Inlet Node Name", " SeriesPIU Secondary Air Inlet Node, !- Secondary Air Inlet Node Name", " SeriesPIU Outlet Node, !- Outlet Node Name", - " Air Terminal Single Duct Series PIU Reheat 1 Fan Outlet, !- Reheat Coil Air Inlet Node Name", " Air Terminal Single Duct Series PIU Reheat 1 Mixer, !- Zone Mixer Name", " Fan System Model 1, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -2014,7 +2010,6 @@ TEST_F(EnergyPlusFixture, VSParallelPIUStagedHeat) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -2217,7 +2212,6 @@ TEST_F(EnergyPlusFixture, VSParallelPIUModulatedHeat) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -2460,7 +2454,6 @@ TEST_F(EnergyPlusFixture, VSSeriesPIUStagedHeat) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -2667,7 +2660,6 @@ TEST_F(EnergyPlusFixture, VSSeriesPIUModulatedHeat) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", @@ -2908,7 +2900,6 @@ TEST_F(EnergyPlusFixture, VSSeriesPIUCool) " SPACE2-1 ATU In Node, !- Supply Air Inlet Node Name", " SPACE2-1 ATU Sec Node, !- Secondary Air Inlet Node Name", " SPACE2-1 In Node, !- Outlet Node Name", - " SPACE2-1 Zone Coil Air In Node, !- Reheat Coil Air Inlet Node Name", " SPACE2-1 PIU Mixer, !- Zone Mixer Name", " SPACE2-1 PIU Fan, !- Fan Name", " Coil:Heating:Electric, !- Reheat Coil Object Type", diff --git a/tst/EnergyPlus/unit/Standard621SimplifiedProcedure.unit.cc b/tst/EnergyPlus/unit/Standard621SimplifiedProcedure.unit.cc index 36bb34b8dca..5a316f499f4 100644 --- a/tst/EnergyPlus/unit/Standard621SimplifiedProcedure.unit.cc +++ b/tst/EnergyPlus/unit/Standard621SimplifiedProcedure.unit.cc @@ -974,7 +974,6 @@ TEST_F(EnergyPlusFixture, SimplifiedProcedureTest1) " Space ATU In Node, !- Supply Air Inlet Node Name", " Space Sec In Node, !- Secondary Air Inlet Node Name", " Space In Node, !- Outlet Node Name", - " PIU Reheat Air Inlet Node, !-Reheat Coil Air Inlet Node Name", " PIU Zone Mixer, !-Zone Mixer Name", " PIU Fan, !-Fan Name", " Coil:Heating:Fuel, !-Reheat Coil Object Type", @@ -1996,7 +1995,6 @@ TEST_F(EnergyPlusFixture, SimplifiedProcedureTest2) " Space ATU In Node, !- Supply Air Inlet Node Name", " Space Sec In Node, !- Secondary Air Inlet Node Name", " Space In Node, !- Outlet Node Name", - " PIU Reheat Air Inlet Node, !-Reheat Coil Air Inlet Node Name", " PIU Zone Mixer, !-Zone Mixer Name", " PIU Fan, !-Fan Name", " Coil:Heating:Fuel, !-Reheat Coil Object Type", @@ -3072,7 +3070,6 @@ TEST_F(EnergyPlusFixture, SimplifiedProcedureTest3) " Space ATU In Node, !- Supply Air Inlet Node Name", " Space Sec In Node, !- Secondary Air Inlet Node Name", " Space In Node, !- Outlet Node Name", - " PIU Reheat Air Inlet Node, !-Reheat Coil Air Inlet Node Name", " PIU Zone Mixer, !-Zone Mixer Name", " PIU Fan, !-Fan Name", " Coil:Heating:Fuel, !-Reheat Coil Object Type",