…ble connection related error reporting when the logger (or inverter) didn't respond properly after 3 tries.
…ble connection related error reporting when the logger (or inverter) didn't respond properly after 3 tries.
Hey @HolBaum5 - I've pushed a new release here: https://github.com/catalinsanda/org.openhab.binding.solarman/releases/tag/v0.3.2 Give it a try and let me know if it solves your problem. |
I have installed the version 0.3.2 and get after 3 connection attempts (the sun has gone down) the following messages.
I'll check tomorrow when the sun is shining again if the data will be output again. |
Hello @catalinsanda, at sunrise-sunset, so in the transition phase I still get the ERROR messages.
Would it be possible to suppress this or make it configurable (under advanced settings in the thing configuration, WARN instead of ERROR)? |
Hi @HolBaum5 - It's OK (expected) to have 3 errors at sunset, when the logger/inverter becomes offline. I wasn't expecting errors at sunrise. This might mean the inverter is flapping between online and offline a bit until there is enough sun. I could apply the same strategy, instead of considering the inverter online on the first successful connection, I could wait a few successful requests before considering it online again and enabling logging. How many errors do you get at sunrise? |
Attached my logs from yesterday (update to 0.3.2 around 21:10) and today. Why I always have a message at 9:40 is not clear to me.
|
I have a Deye 600 Micro inverter.
When the sun is no longer shining, the inverter goes into sleep mode. Then I get lots of error messages in the logger.
Maybe you can determine if the logger is offline and then stop the logging in binding?
The text was updated successfully, but these errors were encountered: