Allow blacklisting sensors #25
Comments
This is by design, on laptops the entire laptop is affected by airflow, and we only have one fan knob. It's not only supposed to be CPU/GPU specific. 67C is very close to recommended maximum operating temperature for basically any NVMe drive, so it's normal to pump a bunch of air in there. It sounds like zcfan is doing the right thing here, that's way too close to max operating temp. |
Thanks for the reply. They never change. I've got the T16 in idle mode... nothing going on and no load on storage. Yes, I see you are right... close to 70 is the danger zone for nvme SSDs... Ok, lets test: The other temp sensor on /sys/class/hwmon/hwmon1/temp3_input is STILL on 67850. Soooo... maybe the actual SSD temp is temp1_input, at around 30 degrees, and temp3_input is not working, or something else? It never changes. |
I'm willing to add a mechanism to disable faulty sensors, but it would need to be robust and not too cumbersome. One of the problems is hwmon ordering is not deterministic. So probably what one would have is, instead, the ability to select which sensor(s) they want by name. Alternatively, we can just look for coretemp/k10temp and only use those sensors. I don't know what the right answer is yet, it requires some thinking in terms of ergonomics and complexity. |
Thanks again for the reply. Yes, you are right. They might change numbers. Or - do make it work with select sensors only, but have them passed in as optional arguments at runtime (not from config), and then leave it to the user to write a script to hunt and filter for the needed sensor paths, and then pass them to the application at runtime. |
Same problem I have with wifi chipset temp... |
@Pyntux - I've cobbled together a crude hard-coded filter into a zcfan, to exclude the one I don't want. It works... but I usually end up with a hard crash on the system if I leave it for an extended period. I think if the system enters standby mode or something - its gone. No coming back. Probably my own bad code somewhere. I didn't expect a bad array pointer or something in a user-space fan-driver could bring down the whole system... I'm contemplating writing my own version of this in something like Python, just for fun, and then maybe later in Rust. Though I'm pondering the use of /proc/acpi/ibm/fan - as it only allows for some 3 pre-set fan temps it seems... The Thinkpad's own thermal management system, which I guess lives in the bios, has much smoother control of the fan (not bracketed speeds). However - it bombs out sometimes (for me at least), and then spins the fan up/down constantly with no hysteresis. |
I noticed my SSD temp (around 67 degs) gets picked up as the temp, and used for the rules, etc.
The SSD temp lives under /sys/class/hwmon/hwmon1/temp*_input.
temp1 is "nvme composite" temp, and "temp2 is nvme sensor 2".
Sensor 2 reads around 67 most of the time.
The SSD is not covered by the Thinkpad cooler (on the T16 at least):
https://laptopmedia.com/wp-content/uploads/2022/08/internals-1000x711.jpg
So, controlling fan temp based on this max temp, is not very useful.
TEMP_FILES_GLOB "/sys/class/hwmon/hwmon*/temp*_input" is too broad.
I think a solution could be to allow an override path for TEMP_FILES_GLOB to be specified in /etc/zcfan.conf
On my system, /sys/class/hwmon/hwmon6/ contains all the CPU and GPU temps.
(I dunno if having a single path override is going to be feasible for some hardware configuration - with dedicated graphics chips, which might be reported under a different /sys/class/hwmon/hwmon*/...)