Description
When both special treatments have to be used (flatfield heuristic identification and passing through the command line the filter wheels 52), osa tries the first 3 times adding to the command the --flatfield-heuristic
but without using the filters 52 via command line. It is only on the 4th try when both arguments are passed and the command runs without problems. In the process, the sequence is vetoed because of the many trials.
This should be fixed to avoid so many unsuccessful repetitions.
lstosa/osa/scripts/calibration_pipeline.py
Lines 165 to 175 in 6a06d7c
try: | |
analysis_step.execute() | |
return analysis_step.rc | |
except Exception: | |
log.info(f"Failed. Return code {analysis_step.rc}") | |
cmd.append("--filters=52") | |
log.info("Trying again by setting filters 52") | |
analysis_step = ChargeCalibrationStage(run=f"{pedcal_run_id:05d}", command_args=cmd) | |
analysis_step.execute() | |
return analysis_step.rc |
I think we tried not using the bare Except here, but somehow it was the easiest thing given the Exception in lstchain onsite calibration script (?). To be revised.