Scripts for automatic SUSEE Streams POC tests

This folder contains two Python3 scripts, and an .env file to perform a multi Sensor test on x86/PC xUnix systems. In this test a number of Sensors are initialized using a single management-console and the Sensor instances send messages periodically to test the iota-bridge under conditions, similar to real world conditions.

These are the used files:

  • .env
    A dotenv file specifiying global test configuration variables.
  • prepare_multi_sensor_test.py
    Creates all folders, copies all applications into the right folder and initializes all Sensors.
  • run_multi_sensor_test.py
    Used to start the multi sensor test after it has been prepared with prepare_multi_sensor_test.py

Prerequisites

  1. Build the project with release profile as been described in the main README file. Though debug profile would also do, it would be very time-consuming, because the POW is very slow for debug builds.

  2. If you use a local IOTA Bridge instance with a private tangle, start the application in a shell on your test as shown below.

    Don't forget to start the docker compose environment for the private tangle before you start the IOTA Bridge as been described here.

    In the ./target/release folder of this repository:

        > ./iota-bridge

    If a production like SUSEE Node for test purposes is used, you don't need to start a local IOTA Bridge instance but you need to edit the following variables in the ./test/scripts/.env file (replace 'iotabridge.example.com' with the domain name of your SUSEE Node) :

Prepare and run the multi Sensor test

Step 1

Open the ./test/scripts/.env file and edit the NUMBER_OF_SENSORS value according to you needs.

Step 2

Open a shell in the ./test/scripts folder and execute

    > python3 prepare_multi_sensor_test.py

The script creates a workspace folder containing a number of initialized Sensors. Each Sensor is contained in its own sensor_# folder, where # denotes the index number of the specific Sensor.

After the folders have been created and all application files have been copied into the right place each Sensor is initialized using a management-console instance that is started in the workspace folder. The Sensor instances are initialized concurrently using the --init-multiple-sensors argument of the Management Console. After all Sensors have been initialized the Management Console will search for further Sensors that are available for initialization in an endless loop. You need to close the terminal that has been used to start the python3 process to kill all spawned sub processes after all Sensors have been initialized.

The output log of the Sensors are written into prepare_multi_sensor_test.log files located in each of the sensor_# folder.

The output log of the management-console is written into a prepare_multi_sensor_test.log file located in the workspace folder.

To find out if all Sensors have been initialized, have a look into the prepare_multi_sensor_test.log in the workspace folder. This log file will contain many "DevEUI: ANY - Received Confirmation::NO_CONFIRMATION" entries like this:

[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION
[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION
[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION
[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION
[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION
[INFO  streams_tools::remote::remote_sensor] DevEUI: ANY - Received Confirmation::NO_CONFIRMATION

There will occur several "DevEUI: ANY - Received Confirmation::NO_CONFIRMATION" messages during the initialization process as the Management Console periodically tries to find new Sensors ready to be initialized. These "DevEUI: ANY - Received Confirmation::NO_CONFIRMATION" messages will be surrounded by other log messages that result from the initialization of other Sensors. If only "DevEUI: ANY - Received Confirmation::NO_CONFIRMATION" messages are logged (as shown above) the initialization of all other Sensors has been finished.

Step 3

In the same shell execute

    > python3 run_multi_sensor_test.py

The script starts each Sensor using the --file-to-send argument so that all Sensors start sending messages immediately. As each Sensor sends the message periodically the test will run until it is cancelled using CTRL+C.

The output log of the Sensors is written into run_multi_sensor_test.log files located in each of the sensor_# folder.

The management-console is not needed for sending messages. Therefore, there is no log file for it.