cycle_min: 0 causes 100% load as timer gets scheduled in a loop with 0 delay #929

Open
mikz opened this issue Feb 24, 2025 · 1 comment
Open
Labels
bug Something isn't working P1 Priority 1

Comments

@mikz
Copy link

mikz commented Feb 24, 2025

Version of the custom_component

main

If it is releveant to regulation performance or optimisation some curves are needed

no

Describe the bug

I configured cycle_min: 0 and Versatile Thermostat goes into infinite interval spawning loop.

async_track_time_interval(
self.hass,
self.async_control_heating,
interval=timedelta(minutes=self._cycle_min),
)

will start spawning cycle jobs with 0 delay causing 100% load.

I know this is poor API from homeassistant and other integrations suffer the same (adaptive lighting).

Yet it can be fixed by either requiring > 0 int in the configuration schema or by having some min(1, timedelta(...)) to have at least some enforced delay.

I learned this the hard way, but having a foolproof setup would prevent some folks going down this rabbit hole.

@jmcollin78
Copy link
Owner

Hello @mikz ,

Yes good point, I will add that. Thank you for your report.

@jmcollin78 jmcollin78 added bug Something isn't working P1 Priority 1 labels Feb 25, 2025