@jmangum

While verifying moment2 (FWHM) image values by comparing spectra toward specific positions in an input spectral line cube with their corresponding FWHM values in the moment2 image, noted significant disagreement near the signal-to-noise clip limit (i.e. 3-sigma). Attached is an example where the FWHM of the line (HCN 1-0) appears to be about 75 km/s, but the FWHM value from the moment2 image is about 25 km/s. This difference is rather systematic along the boundaries of the FWHM image.
Screenshot 2023-09-26 at 10 31 07 AM