Skip to content

mangOH Red Mediatek Wifi does not allow a stop and then start on Legato 19.10. #89

@zchowdhury

Description

@zchowdhury

wifi client disconnect and then wifi client stop are the suggested Legato commands needed to bring
down a Wifi interface and later wifi client start ... can be used to restart the interface. This does not
work as the mt7697 core driver does not exit on a disconnect, nor on a stop, It seems some iproute2
interface issues while the supplicant is kept running. Doing everything manually, with killing
procs and rmmod drivers works but Legato is out of sync and things never work again. Note Legato
tries to always keep the supplicant up on 19.10.