Notifications
You must be signed in to change notification settings - Fork 0
Description
When registering the valid range attribute for "u_ref", the code crashed because there is a type mismatch for valid_range.
The attribute type obtained from "get_attribute_type" is a 5 (float), and the variable type obtained from "get_attribute_type" is a 6 (double).
axtype = get_attribute_type(fileobj%ncid, varid, attribute_name) xtype = get_variable_type(fileobj%ncid, varid) if (axtype .ne. xtype) then call error("type mismatch for valid_range.") endif
traceback:
fms_lad2_xanadu.x 00000000023C5A08 mpp_mod_mp_mpp_er 69 mpp_util_mpi.inc
fms_lad2_xanadu.x 0000000002520520 fms_io_utils_mod_ 144 fms_io_utils.F90
fms_lad2_xanadu.x 00000000026CDA51 netcdf_io_mod_mp_ 153 register_variable_attribute.inc
fms_lad2_xanadu.x 0000000001D6CC95 diag_output_mod_m 969 diag_output.F90
fms_lad2_xanadu.x 0000000000E49151 diag_util_mod_mp_ 2185 diag_util.F90
fms_lad2_xanadu.x 0000000000E5D12B diag_util_mod_mp_ 2633 diag_util.F90
fms_lad2_xanadu.x 0000000000E54D8C diag_util_mod_mp_ 2529 diag_util.F90
fms_lad2_xanadu.x 00000000023490EE diag_manager_mod_ 3511 diag_manager.F90
fms_lad2_xanadu.x 0000000002222745 diag_manager_mod_ 2008 diag_manager.F90
fms_lad2_xanadu.x 0000000002212B9A diag_manager_mod_ 1550 diag_manager.F90
fms_lad2_xanadu.x 00000000008BB07B land_tile_diag_mo 1069 land_tile_diag.F90
fms_lad2_xanadu.x 00000000008B0D6F land_tile_diag_mo 916 land_tile_diag.F90
fms_lad2_xanadu.x 00000000007CCE6C land_model_mod_mp 1184 land_model.F90
fms_lad2_xanadu.x 000000000040D556 MAIN__ 890 coupler_main.F90