Skip to content

Distortion of ASRC  #153

@jian-yuan-cmd

Description

@jian-yuan-cmd

Hardware uses L71 board;
Software reference: https://www.xmos.com/documentation/XM-014785-PC/html/doc/programming_guide/asrc/overview.html

After compilation, download the firmware into the L71 board;
The customer tested the ASRC performance using AP and found two types of ASRC distortion:

1 .
0dB sine wave distortion:
it is OK after adjusting the signal amplitude to -0.1dB;

2
Distortion after AP switching sampling frequency:
for example:
After switching the sampling frequency of the AP instrument’s I2S_output from 44.1KHz to 48KHz,
The frequency of the 1KHz sine wave output by the AP instrument had changed to 0.9KHz after process by XU316_ASRC task;
It seems that the ASRC task has not detect the changes of I2S_Slave’s sampling frequency.
In this case, if turn off the I2S output of the AP instrument and then turn it on, the ASRC output will be OK.