When using the Microsoft usbaudio2 driver instead of the Thesycon driver, there are problems with the configuration of the device in the Windows sound menu:
- for all configs with more than two channels, the playback sample rate cannot be changed: the drop-down menu is greyed-out
- for
2AMi2o2xxxxxx, the playback sample rate can be changed, but the menu is limited to16-bit 44100,24 bit 44100and16-bit 48000 - for all configs, the recording sample rate list has all frequencies, but only 24-bit, not 16-bit
This was tested on an HP laptop running Windows 11 build 22631.2861
With the Thesycon driver installed (but running exactly the same firmware on the MCAB), both the playback and record menus contain all sample rates and all bit depths.