General:

  • removed unused icons directory
  • restrict nx_server log size and location
  • added a reset to base data directory button for contact sheet (data viewer)
  • strip tool scaling now set in beamline config .ini file
  • removed pixmap delegate from scan queue progress widget
  • common code to load a NXstxm hdf5 file now skips the instrument folder in the data and returns only the data specified in the 'default' attributes

BlueSky:

  • disabled progressive stack in beamline config .ini file, design needs rethink to avoid random json serialization error
  • added sim devices

Pixelator:

  • specify when to update the scan plot as a percentage of scan completion to improve plotting performance
  • fixed scan progress reporting to scan queue progress widget
  • default sample scans to "Constant Velocity" instead of "Point by Point"

@RussBerg RussBerg merged commit bc2f5a1 into master Mar 20, 2026