Confusion matrix and F-beta lose false positives and negatives above 2**24 voxels #9270
get_confusion_matrix and get_f_beta_score cast tp, tn and p to float32 before they compute fn = p - tp and fp = n - tn. float32 holds integers exactly only up to 2**24 (16,777,216). In a sample with more voxels per channel, n and tn round to the float32 step, so fp and fn round too.
This is a follow-up to #7186. #7187 moved the sums to integers, but the counts are still cast to float32 before the subtractions.
To Reproduce
Synthetic masks, one CT-sized sample (512 x 512 x 300 = 78,643,200 voxels):
fp is 1 and precision is 50/51 = 0.9804. In this volume fp can only be 0 or a multiple of 8 (the float32 step between 226 and 227). With 0 to 6 real false positives, dev reports 0, 8, 8, 8, 8, 8, 8.
This affects ConfusionMatrixMetric (all metric names) and FBetaScore for samples above 2**24 voxels, for example whole-body CT and large 2D pathology tiles (4096 x 4098 is already above the limit).
Environment
MONAI dev at 846ae34, torch 2.15.0, Python 3.11.6, macOS 15.6.1 arm64 (CPU).
Additional context
I have a fix with tests and will open a PR that links this issue.
AI disclosure: this issue was found and written with Claude Code (an AI coding tool).