@@ -0,0 +1,18 @@
name: room-air-conditioner-cooling-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,27 @@
name: room-air-conditioner-cooling-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,22 @@
name: room-air-conditioner-fan-cooling-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,31 @@
name: room-air-conditioner-fan-cooling
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,22 @@
name: room-air-conditioner-fan-heating-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,31 @@
name: room-air-conditioner-fan-heating-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,24 @@
name: room-air-conditioner-fan-wind-heating-cooling-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
name: room-air-conditioner-fan-wind-cooling-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,26 @@
name: room-air-conditioner-fan-wind-heating-cooling-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,24 @@
name: room-air-conditioner-fan-wind-heating-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
name: room-air-conditioner-fan-wind-heating-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,20 @@
name: room-air-conditioner-heating-cooling-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,18 @@
name: room-air-conditioner-heating-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,27 @@
name: room-air-conditioner-heating-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,22 @@
name: room-air-conditioner-humidity-cooling-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,32 @@
name: room-air-conditioner-humidity-cooling-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner

Original file line number Diff line number Diff line change
@@ -0,0 +1,24 @@
name: room-air-conditioner-humidity-fan-cooling-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
name: room-air-conditioner-humidity-fan-cooling-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,26 @@
name: room-air-conditioner-humidity-fan-heating-cooling-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,24 @@
name: room-air-conditioner-humidity-fan-heating-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
name: room-air-conditioner-humidity-fan-heating-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,24 @@
name: room-air-conditioner-humidity-heating-cooling-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,22 @@
name: room-air-conditioner-humidity-heating-only-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
Original file line number Diff line number Diff line change
@@ -0,0 +1,32 @@
name: room-air-conditioner-humidity-heating-only
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatOperatingState
version: 1
config:
values:
- key: "thermostatOperatingState.value"
enabledValues:
- idle
- cooling
- heating
- id: airConditionerFanMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner

Original file line number Diff line number Diff line change
@@ -0,0 +1,28 @@
name: room-air-conditioner-nostate
components:
- id: main
capabilities:
- id: switch
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: thermostatMode
version: 1
- id: thermostatHeatingSetpoint
version: 1
- id: thermostatCoolingSetpoint
version: 1
- id: airConditionerFanMode
version: 1
- id: fanSpeedPercent
version: 1
- id: windMode
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirConditioner
8 changes: 5 additions & 3 deletions drivers/SmartThings/matter-thermostat/src/init.lua
Original file line number Diff line number Diff line change
@@ -677,16 +677,18 @@ local function match_profile(driver, device)
local thermostat_modes = create_thermostat_modes_profile(device)
if thermostat_modes == "" then
profile_name = profile_name .. "-heating-cooling"
else
device.log.warn_with({hub_logs=true}, "Device does not support both heating and cooling. No matching profile")
elseif thermostat_modes == "No Heating nor Cooling Support" then
device.log.warn_with({hub_logs=true}, "Device does not support either heating or cooling. No matching profile")
return
else
profile_name = profile_name .. thermostat_modes
end

if profile_name == "room-air-conditioner-humidity-fan-wind-heating-cooling" then
profile_name = "room-air-conditioner"
end

if not running_state_supported and profile_name == "room-air-conditioner-fan-heating-cooling" then
if not running_state_supported then
profile_name = profile_name .. "-nostate"
end