Matterbridge plugin that bridges Wirenboard devices to the Matter ecosystem. Connects to the Wirenboard MQTT broker, discovers devices automatically, and exposes them to Apple Home, Google Home, Amazon Alexa, and SmartThings — all local, no cloud.
Wirenboard devices are discovered via standard WB MQTT conventions (/devices/+/meta, /devices/+/controls/+/meta). Each control is mapped to the appropriate Matter device type based on its type and units. State changes sync bidirectionally: MQTT values update Matter attributes, and Matter commands publish to MQTT /on topics.
- Automatic device discovery via MQTT meta-topics (retained messages)
- Bidirectional state sync: MQTT → Matter and Matter → MQTT
- Supports all standard WB control types (see mapping table)
- Two grouping modes: per-device (fewer Matter nodes) or per-control (granular)
- White list / black list filtering
- Static discovery mode: wait at startup until each id in
devicesappears in MQTT discovery (see Static discovery) - TLS support:
mqtts,wss, mutual TLS, self-signed certificates - Device overrides: rename, retype, or skip individual controls
- Composite thermostat detection (setpoint + temperature + mode)
- Failsafe: refuse startup if fewer than N devices are found (prevents config loss on network issues)
- Hardware metadata extraction: serial number, firmware version, hardware revision (peripheral WB devices)
- Controller device
system: readonlytextcontrols (e.g. Short SN, Batch No, manufacturing date) are mapped into Matter Bridged Device Basic Information on the Matter node that represents the controller — whengroupingModeisdevice. WithgroupingMode: "control", the plugin does not attach that extended factory snapshot to a single controller node (each control would be its own node); usedevicegrouping for the controller if you want serial/part number and related fields visible in the app.
| Requirement | Version |
|---|---|
| Matterbridge | >= 3.7.0 |
| Node.js | 20.19+ / 22.13+ / 24+ |
| MQTT broker | Wirenboard controller or any Mosquitto instance |
Developing this plugin from source: the repo does not list matterbridge as an npm dependency. Run npm run dev:link after npm install so matterbridge is symlinked into node_modules (same idea as the official plugin template). Without that link, npm run build and tests will fail with unresolved matterbridge imports.
Open the Matterbridge web UI, find matterbridge-wirenboard-plugin, and click Install.
sudo npm install -g matterbridge-wirenboard-plugin --omit=dev
matterbridge -add matterbridge-wirenboard-pluginInstall Matterbridge globally (npm install -g matterbridge) or from a local clone (cd matterbridge && npm link). Then link it into this project:
git clone https://github.com/your-org/matterbridge-wirenboard-plugin
cd matterbridge-wirenboard-plugin
npm install
npm run dev:link # required: wires matterbridge into node_modules for tsc / jest
npm run build
matterbridge -add .npm run dev:link runs npm link matterbridge (see package.json scripts).
Configuration is stored in ~/.matterbridge/matterbridge-wirenboard-plugin.config.json.
| Field | Type | Default | Description |
|---|---|---|---|
mqttHost |
string | "localhost" |
MQTT broker hostname or IP |
wirenboardUrl |
string | "" |
Full URL for the Matterbridge device Url link (Wirenboard web UI or proxy). Empty → http://<mqttHost> |
mqttPort |
number | 1883 |
MQTT broker port |
mqttUsername |
string | "" |
MQTT username (leave empty if not required) |
mqttPassword |
string | "" |
MQTT password |
mqttProtocol |
string | "mqtt" |
Transport: mqtt, mqtts, ws, wss |
mqttCaPath |
string | "" |
Path to CA certificate (PEM) for TLS |
mqttCertPath |
string | "" |
Path to client certificate (PEM) for mutual TLS |
mqttKeyPath |
string | "" |
Path to client private key (PEM) for mutual TLS |
discoveryMode |
string | "auto" |
auto — idle-based discovery complete; static — wait until each id in devices appears (startup only; see Static discovery) |
discoveryTimeout |
number | 30 |
Max seconds to wait for discovery (auto mode) |
discoveryIdleMs |
number | 1000 |
Idle time (ms) on meta-topics before discovery is considered complete |
groupingMode |
string | "device" |
device — one Matter node per WB device; control — one Matter node per control |
includeHidden |
boolean | false |
Include controls marked hidden in WB meta |
ignoreSystemPrefixedDevices |
boolean | true |
When true, does not bridge Wirenboard service devices whose id starts with system__ (e.g. system__networks__…), and unmappable controls on those devices (if bridged) log at debug only. Set false to expose system__* in Matter and use warn for unmappable-control skips there. |
ignoreNetworkPrefixedDevices |
boolean | true |
When true, does not bridge devices whose id starts with network (e.g. networks, networks_…). Independent of ignoreSystemPrefixedDevices. Set false to bridge them. |
devices |
string[] | [] |
Device ids required at startup when discoveryMode is static (not a registration filter; see Static discovery) |
whiteList |
string[] | [] |
Only expose listed devices (empty = all) |
blackList |
string[] | [] |
Never expose listed devices |
deviceOverrides |
object | {} |
Per-device overrides (see Advanced) |
failsafeCount |
number | 0 |
Min devices required on startup (0 = disabled) |
debug |
boolean | false |
Enable verbose debug logging |
{
"name": "matterbridge-wirenboard-plugin",
"type": "DynamicPlatform",
"mqttHost": "192.168.1.100",
"mqttPort": 1883,
"mqttUsername": "",
"mqttPassword": "",
"mqttProtocol": "mqtt",
"discoveryMode": "auto",
"discoveryTimeout": 30,
"discoveryIdleMs": 1000,
"groupingMode": "device",
"includeHidden": false,
"ignoreSystemPrefixedDevices": true,
"ignoreNetworkPrefixedDevices": true,
"whiteList": [],
"blackList": ["wb-hwmon_0"],
"deviceOverrides": {},
"failsafeCount": 5,
"debug": false
}The plugin chooses Matter mappings for value channels from meta.units on each control (/devices/<id>/controls/<control>/meta in MQTT). Newer wb-mqtt-serial MAP device templates include "units" on channels so this works out of the box. If your controller still runs an older wb-mqtt-serial build without those template fields, controls may have no units in MQTT and the plugin will skip them or only map legacy normalized types (e.g. deprecated power → W).
Until you upgrade wb-mqtt-serial, you can fix this in wb-mqtt-serial configuration (not in Matterbridge):
-
Merge
unitsin the serial device definition (recommended) In the Wiren Board UI (Settings → Serial devices) or in/etc/wb-mqtt-serial.conf, open the MAP device and add achannelsarray where each entry setsnameexactly as in the device template (same English string as in the template file, e.g.Q L1,Urms L1,EPP) and the desiredunitsstring. Per wb-mqtt-serial docs, when a channel name matches the template, properties from the device config are merged with the template and override the template if both set the same field—so you only needname+unitsfor each channel that is missing units. -
Custom template copy Copy the MAP JSON from
/usr/share/wb-mqtt-serial/templates/(e.g.config-map12e.json) into/etc/wb-mqtt-serial.conf.d/templates/, add"units": "…"under eachchannels[]entry that needs it, then select that template /device_typefor the device. Use this if you prefer one file with full control.
Use units strings that match the sensor mapping table and your plugin version (newer releases add MAP electrical units such as var, VA, Hz, deg, ratio, kvarh, kVAh). Copy spelling exactly from the wb-mqtt-serial MAP templates when in doubt (units is case-sensitive).
Why % and “humidity” appear together: the plugin’s default for value + % is relative humidity (climate sensors). MAP may also use % for THD (harmonics). Those MAP channels are not humidity — give the control a name that matches the plugin’s harmonic keywords (THD, harm, …) so mapping goes to electrical, not humiditySensor.
MAP electrical Matter proxies (limitation of the default Matter server on the bridge): THD % (with harmonic keywords) is stored in rmsPower (scale ≈ THD×100, not true RMS watts). Phase angle deg is stored in rmsCurrent as millidegrees (×1000), not amperes. kvarh / kVAh use the same cumulativeEnergyImported struct as kWh, one Matter endpoint per WB counter channel.
After saving config, restart wb-mqtt-serial and confirm under MQTT that each control’s meta includes the expected units, then restart or reconnect Matterbridge if needed.
WB meta.type |
Condition | Matter Device Type | Matter Cluster |
|---|---|---|---|
switch |
writable | onOffOutlet |
OnOff |
switch |
readonly | contactSensor |
BooleanState |
switch |
name contains valve/кран |
waterValve |
ValveConfigurationAndControl |
switch |
name contains lock/замок |
doorLockDevice |
DoorLock |
switch |
name contains fan/вент |
fanDevice |
FanControl |
switch |
name contains pump/насос |
pumpDevice |
OnOff + PumpConfigurationAndControl |
switch |
name contains motion/движ/occupancy (readonly) |
occupancySensor |
OccupancySensing |
range |
— | dimmableLight |
OnOff + LevelControl |
range |
name contains blind/curtain/штор/жалюзи |
coverDevice |
WindowCovering |
range |
name contains fan/вент + speed |
fanDevice |
FanControl |
rgb |
— | extendedColorLight |
OnOff + ColorControl |
pushbutton, wo-switch |
— | genericSwitch |
Switch (MomentarySwitch) |
WB meta.type |
meta.units |
Matter Device Type | Matter Cluster |
|---|---|---|---|
value |
deg C |
temperatureSensor |
TemperatureMeasurement |
value |
%, RH |
humiditySensor |
RelativeHumidityMeasurement |
value |
% + name hints THD/harm/… |
electricalSensor |
ElectricalPowerMeasurement (THD proxy, see AGENTS.md) |
value |
Pa / mbar / bar |
pressureSensor |
PressureMeasurement |
value |
lx |
lightSensor |
IlluminanceMeasurement |
value |
W / V / A / mA / mV |
electricalSensor |
ElectricalPowerMeasurement |
value |
var / VA / Hz / ratio |
electricalSensor |
ElectricalPowerMeasurement |
value |
deg (not deg C) |
electricalSensor |
ElectricalPowerMeasurement (phase-angle proxy) |
value |
kWh / kvarh / kVAh |
electricalSensor |
ElectricalEnergyMeasurement |
value |
m³/h |
flowSensor |
FlowMeasurement |
value |
ppm (CO2) |
airQualitySensor |
AirQuality + CarbonDioxideConcentrationMeasurement |
value |
ppm (CO, by name) |
airQualitySensor |
AirQuality + CarbonMonoxideConcentrationMeasurement |
value |
ppb (NO2, by name) |
airQualitySensor |
NitrogenDioxideConcentrationMeasurement |
value |
µg/m³ (PM1/PM2.5/PM10, by name) |
airQualitySensor |
Pm1/Pm25/Pm10ConcentrationMeasurement |
value |
ppb/ppm (TVOC, by name) |
airQualitySensor |
TotalVolatileOrganicCompoundsConcentrationMeasurement |
alarm |
name contains smoke/дым |
smokeCoAlarm |
SmokeCoAlarm |
alarm |
name contains leak/утечка |
waterLeakDetector |
BooleanState |
alarm |
name contains freeze/замерз |
waterFreezeDetector |
BooleanState |
alarm |
name contains rain/дождь |
rainSensor |
BooleanState |
alarm |
(fallback) | contactSensor |
BooleanState |
Deprecated WB types (temperature, rel_humidity, voltage, power, current, etc.) are automatically normalized to value + appropriate units.
Types without a Matter equivalent (text, enum without override, sound_level, wind_speed, rainfall) are skipped with a warning in the log.
| Feature | Apple Home | Google Home | Amazon Alexa | SmartThings |
|---|---|---|---|---|
| On/Off outlets & lights | Yes | Yes | Yes | Yes |
| Dimmers (LevelControl) | Yes | Yes | Yes | Yes |
| Color lights (RGB) | Yes | Yes | Yes | Yes |
| Temperature sensors | Yes | Yes | Yes | Yes |
| Humidity sensors | Yes | Yes | Yes | Yes |
| Pressure sensors | Partial¹ | Yes | No | Yes |
| Air quality sensors | Yes | Yes | Yes | Yes |
| Electrical sensors | No | No | No | No |
| Flow sensors | No | Yes | No | Yes |
| Occupancy sensors | Yes | Yes | Yes | Yes |
| Contact sensors | Yes | Yes | Yes | Yes |
| Smoke/CO alarms | Yes² | Partial³ | Yes | Yes |
| Water leak detectors | Yes² | No | No | Yes |
| Water valve | Partial⁴ | No | No | Yes |
| Window coverings | Yes | Yes | Yes | Yes |
| Door locks | Yes | Yes | Yes | Yes |
| Fan control | Yes | Yes | Yes | Yes |
| Thermostats | Yes | Yes | Yes | Yes |
| Pump | No | Yes | No | Yes |
| Generic switch (pushbutton) | Yes⁵ | Partial | Yes | Yes |
| Max bridged endpoints | 150 | ~250 | 50 | ~50 |
¹ Pressure: Apple Home has no dedicated UI tile but automations work. ² Requires iOS 18.4+. ³ Google Home: full support for Nest Protect; partial for third-party Matter smoke alarms. ⁴ Water valve pairs but has no native Apple Home UI; works via automations. ⁵ Improved in iOS 18.2 (moved to Home View).
Alexa hard limit: 50 bridged devices. Use whitelist/blacklist to stay within the limit. Apple Home limit is 150 (149 + bridge). Electrical sensors and rain/freeze detectors are not supported by any major controller.
Sources:
- Apple Home — Matter accessories
- Apple Home — iOS 18.4 smoke/CO/water leak
- Google Home — Supported Matter device types
- Amazon Alexa — Supported Matter device categories
- Samsung SmartThings — Matter support
- Matterbridge — Controller limits and compatibility
- Bridge endpoint limits: 1Home — Alexa (50 hard limit), 1Home — Google Home (~250), 1Home — SmartThings (~50), Apple Home 150 limit (community)
One Matter bridged device per WB device. Each control becomes a child endpoint inside that device.
- Fewer Matter nodes — better for controllers with endpoint limits
- All relays of
wb-mr6cappear as one device with multiple outlets - Recommended for most setups
- Required if you want full Bridged Device Basic Information (factory metadata) on the Wirenboard controller device id
system
One Matter bridged device per WB control.
- Full granularity — each control appears separately in the controller app
- Better naming and room assignment in Apple Home / Google Home
- Reaches Matter endpoint limits faster (~250 total)
- Recommended when you have few devices but want per-control visibility
- For WB device
system, extended controller metadata in Matter BI is not merged onto one dedicated node (see below); preferdevicegrouping for the controller if you rely on that metadata
The WB MQTT device id system represents the Wirenboard controller (factory info: Short SN, Batch No, firmware strings, etc.). The plugin maps readonly text controls from that device into Matter Bridged Device Basic Information — but only when it can attach them to one Matter bridged device that stands for the whole controller.
-
groupingMode: "device"— there is exactly one Matter node per WB device, includingsystem. All service controls are child endpoints under that node (or the node is root-only if there are no mappable controls). The plugin setssystemBiEndpointto that node and writes the extended BI snapshot there. Use this mode if you want serial/part number and related fields visible in Apple Home / Google Home for the controller. -
groupingMode: "control"— each WB control becomes its own Matter bridged device. Forsystemthat means many small devices (one per text/control), and there is no single “controller” node the plugin currently uses for the full extended BI block. Factory metadata is therefore not merged into one dedicated controller card in this mode (implementation detail:systemBiEndpointis only set in thedeviceaggregation path).
Practical rule: need factory/controller info in Matter → groupingMode: "device" (default). Fine-grained per-control exposure for other WB devices can still be a reason to use control elsewhere, but for system specifically, prefer device.
deviceType: use Matterbridge export names (e.g. onOffOutlet, onOffLight), not Matter DeviceTypeDefinition.name strings (e.g. MA-onoffpluginunit). The allowed values are exactly the Matter device types that appear in CONTROL_MAPPINGS in controlMapping.ts. The same list is written into the deviceType enum in matterbridge-wirenboard-plugin.schema.json when you run npm run build (from MATTER_DEVICE_TYPE_BY_NAME). Types that only exist on composite code paths are not valid here — for example you cannot set deviceType: "thermostatDevice" on a single arbitrary control; a thermostat is created when Thermostat composite detection matches your WB metadata.
Per-device keys are WB device ids. Each value must include controls (object). Optional name sets the Matterbridge UI / registration title for that device. Under controls, each key is a WB control name; the value may set deviceType (string, as above) or skip: true (no endpoint, no “unmappable control” warning for that control).
Example full config:
{
"deviceOverrides": {
"wb-mr6c_28": {
"name": "Lighting Panel",
"controls": {
"Relay 1": { "deviceType": "onOffLight" },
"Relay 2": { "deviceType": "onOffLight" },
"Temperature": { "skip": true }
}
},
"wb-map12e_42": {
"controls": {
"Channel 1 Power": { "skip": true }
}
}
}
}If a WB device has controls matching this combination, the plugin creates a thermostatDevice instead of separate sensor/range endpoints:
| Required | WB control name contains | WB type | Maps to |
|---|---|---|---|
| Yes | temperature (readonly) |
value, deg C |
localTemperature |
| Yes | setpoint or target |
range, deg C |
occupiedHeatingSetpoint / occupiedCoolingSetpoint |
| No | mode or system_mode |
enum |
systemMode (Off/Heat/Cool/Auto) |
Heating-only or cooling-only is detected automatically from available controls. Min/max setpoint bounds are taken from meta.min/meta.max of the setpoint control.
This path is automatic — deviceOverrides cannot turn a single control into a thermostatDevice; that string is not in the override enum because it is not a row in CONTROL_MAPPINGS for individual controls.
With discoveryMode: "static" and a non-empty devices array, startup waits (up to discoveryTimeout) for each listed Wiren Board device id to show up in retained MQTT discovery — instead of using the idle-based “discovery complete” condition from discoveryIdleMs.
Registration is unchanged: registerDiscoveredDevices still iterates every device present in the in-memory map (everything the broker retained on /devices/+/meta). The devices list is not a filter that hides other devices from Matter. Use whiteList / blackList if you need to restrict what gets bridged.
For a checklist of ids you care about before bridging starts, combine static + devices with the MQTT inventory CLI (it annotates whether an id is in devices when discoveryMode is static).
{
"discoveryMode": "static",
"devices": ["wb-mr6c_28", "wb-msw-v3_42", "thermostat-room1"]
}{
"mqttProtocol": "mqtts",
"mqttPort": 8883,
"mqttCaPath": "/etc/ssl/certs/my-ca.pem",
"mqttCertPath": "/etc/ssl/certs/client.pem",
"mqttKeyPath": "/etc/ssl/private/client.key"
}Compiled from this package as dist/mqttInventoryCliEntry.js (thin entry; core logic in mqttInventoryCli.js). It connects to the same MQTT broker fields as the plugin (mqttHost, mqttPort, TLS paths, …), walks /devices/# like the platform, and prints human or --json output with annotations: how whiteList / blackList, deviceOverrides, includeHidden, prefix skips, discoveryMode + devices, and groupingMode would affect Matter exposure — using the same helpers as WirenboardPlatform / WirenboardDevice (not a second implementation).
Run (after npm run build):
npm run verify:mqtt -- --help
node dist/mqttInventoryCliEntry.js --jsonWhen the package is installed with a global or local node_modules/.bin, the mb-wirenboard-verify-mqtt binary points at the same file.
Config file resolution (plugin JSON shape, same filename as Matterbridge):
--config <path>if givenMATTERBRIDGE_WIRENBOARD_PLUGIN_CONFIGif set- First existing readable file among:
/root/.matterbridge/matterbridge-wirenboard-plugin.config.json, then$HOME/.matterbridge/matterbridge-wirenboard-plugin.config.json
MQTT overrides for a single run (highest precedence first): CLI flags → WB_MQTT_* env (table in AGENTS.md) → values from JSON → defaults.
Output: --json writes a single JSON object to stdout (no ANSI). Otherwise, text mode prints a short Legend, effective annotation flags (includeHidden, prefix-ignore toggles), then per device: separator line ── id ──, human-readable title, control counts (total / mappable / unmappable), a single plain-English matter: line (registration outcome), optional static devices[] note, a note when prefix-skip still lists mappable controls (inventory vs Matter), then control rows with badges. It uses ANSI background badges for categories (256-color palette), unless stdout is not a TTY, NO_COLOR is set, or --no-color is passed — then badges render as plain [label] brackets. Mapping: hidden (purple-gray), override (green), skip (orange), blacklist / whitelist (reds / greens), prefix (purple), static (blue), mappable / unmappable (green / gray).
Annotation scope: the CLI explains bridge-relevant options (MQTT connection, lists, overrides, hidden, discovery, groupingMode). It does not diagnose unrelated knobs such as failsafeCount, discoveryTimeout timing semantics beyond what is printed, unregisterOnShutdown, or wirenboardUrl — treat those as out of scope for inventory output.
Authoring workflow: edit ~/.matterbridge/matterbridge-wirenboard-plugin.config.json, run the CLI against it (--config or default paths), adjust whiteList / deviceOverrides / etc. using real device ids (── … ── in human output or devices[].id in --json) and control names from the report. Valid deviceType strings for overrides are the same enum matterbridge-wirenboard-plugin.schema.json regenerates on npm run build ($defs.matterDeviceTypeEnum).
Minimal fragments (merge into your plugin JSON alongside mqttHost and other keys):
{
"whiteList": ["wb-mr6c_28", "wb-msw-v3_42"],
"blackList": ["wb-hwmon_0"]
}{
"deviceOverrides": {
"wb-mr6c_28": {
"name": "Hall relays",
"controls": {
"Relay 1": { "deviceType": "onOffLight" },
"Temperature": { "skip": true }
}
}
}
}npm install
npm run build # compile TypeScript → dist/; refresh matterbridge-wirenboard-plugin.schema.json (deviceType enum from CONTROL_MAPPINGS)
npm run watch # watch mode
npm run cleanBuild # clean + buildDuring startup, SIGINT / SIGTERM aborts further device registration (and stops MQTT) so the service does not stay blocked until every Matter endpoint is created. A single long registerDevice call may still run until Matterbridge finishes that call.
npm test # run all tests
npm run test:watch # watch mode
npm run test:verbose # verbose outputsrc/
module.ts # WirenboardPlatform — entry point, lifecycle
wirenboardMqtt.ts # MQTT client, topic parsing, event emitter
wirenboardDevice.ts # Matter endpoint construction, bidirectional state sync
systemMetadataMapping.ts # WB `system` controller → Bridged Device Basic Information
wirenboardTypes.ts # TypeScript interfaces for WB MQTT conventions
controlMapping.ts # WB control type → Matter device type mapping table
test/
*.test.ts # unit tests (Jest)
Edit src/controlMapping.ts. Each entry specifies the WB type/units match, the target Matter device type, cluster setup, and value converters (MQTT string → Matter attribute and reverse).
The following device types are planned for future releases pending Matter controller support:
| WB Device / Use Case | Planned Matter Type |
|---|---|
| Soil moisture sensors | soilMoistureSensor |
| Gate / garage door controls | closureSensor, closureDevice |
| Irrigation zone valves | irrigationSystem |
Apache-2.0 — see LICENSE.