Expertise modulates automation bias and sentinel behavior in human-AI collaborative diagnosis of neonatal pneumoperitoneum
Lee et al. — submitted to npj Digital Medicine; currently in revision (round 1).
One-line takeaway: AI reliability does not translate linearly into clinical benefit. In 1,750 interpretation events across a multi-reader multi-center crossover study, high AI reliability paradoxically induced automation bias in trainees, while error-prone AI triggered sentinel (vigilant) behavior in experts — demonstrating that adversarial resilience, not standalone accuracy, is the defining metric of human-AI team performance.
Medical AI is often validated under an additive assumption that algorithmic sensitivity and clinician oversight will combine to improve care. We tested this assumption in the high-stakes diagnosis of neonatal pneumoperitoneum, a time-critical surgical emergency. In a multi-reader crossover study analyzing 1,750 interpretation events, clinicians reviewed radiographs aided by either a high-reliability model or a systematically error-injected model. We found that high AI reliability paradoxically induces automation bias in trainees, who accepted 52.0% of incorrect suggestions, while offering limited gains to experts. Conversely, when challenged by flawed AI, the three participating neonatologists exhibited a "sentinel behavior" phenotype, correctly overriding 91.7% of errors (Wilson 95% CI 83.0–96.0%) consistent with increased deliberation; given the small specialist cohort, this finding is hypothesis-generating and warrants prospective replication. We operationalize systemic resilience as the capacity to maintain diagnostic integrity under algorithmic failure and demonstrate that clinical validity depends on the human-AI team's adversarial resilience rather than standalone accuracy. To mitigate the risk of deskilling and never-skilling, we release an open-source educational sandbox designed to inoculate clinicians against automated errors.
Keywords: Neonatal pneumoperitoneum · Automation bias · Sentinel behavior · Artificial intelligence · Deep learning · Multi-reader multi-case study · Human-AI interaction · Radiology
Try it live: neonatal-ai-sandbox.pages.dev
An open-source, web-based educational tool designed to inoculate clinicians against automated errors — simulating both reliable and error-prone AI assistance to build adversarial resilience in trainees and practicing clinicians.
To ensure that differences in reader behavior were driven solely by AI reliability (and not model capacity), both the Reliable and Error-Injected assistants use the same underlying architecture:
- Backbone: RAD-DINO (ViT-B/14) — a vision foundation model pre-trained on large-scale radiology datasets
-
Adaptation (LoRA): Parameter-efficient fine-tuning via Low-Rank Adaptation (
$r=12, \alpha=24$ ) injected into Query/Value projections and the MLP layer; only 1.36% of parameters were trainable - Sampling Strategy (RFBS): A custom Representation-Focused Batch Sampler enforcing diversity and exposure to uncommon pneumoperitoneum distributions during training
Error-Injected model: Same architecture, trained on systematically poisoned labels. False positives engineered by mislabeling clinically plausible confounders (iatrogenic devices, portal venous gas, pneumatosis intestinalis, abdominal drains) as pneumoperitoneum — curated by a board-certified pediatric radiologist to simulate realistic deployment failures rather than random noise.
Neonatal pneumoperitoneum is a time-critical surgical emergency. Integrating AI into this workflow is not just about model accuracy. Clinicians interact with advice, confidence cues, and time pressure.
This study investigates the Human-AI Interaction (HAI) layer:
- Automation Bias: When AI is highly capable, does it help — or does it reduce human vigilance?
- The Sentinel Effect: When AI is systematically wrong, do clinicians disengage, blindly follow, or become hyper-vigilant?
- Expertise Gradient: Do neonatologists, radiologists, and residents react differently to the same AI signals?
- Never-Skilling Risk: Does early-career reliance on reliable AI prevent trainees from developing independent pattern recognition?
| Cohort | Radiographs | Positive Cases | Source |
|---|---|---|---|
| Internal Development | 688 (from 216 patients) | 310 | Asan Medical Center |
| External Validation (Reader Study) | 125 | 40 | 11 tertiary hospitals via AI-Hub |
-
Participants (N=14):
- Pediatric Radiologists:
$n=6$ (mean experience 16.2 ± 4.2 years) - Neonatologists:
$n=3$ (mean experience 10.3 ± 1.5 years) - Radiology Residents:
$n=5$ (mean experience 2.2 ± 1.3 years)
- Pediatric Radiologists:
- Design: Two-session, counterbalanced MRMC crossover with 6-week washout; double-masked
- Total interpretation events: 1,750
Case Allocation (Stratified, N=125):
| Condition | Cases |
|---|---|
| Unaided | 41 |
| Reliable AI | 40 |
| Error-Injected AI | 44 |
Reliability was fixed at the case level. Readers were blinded to the reference standard and unaware of the two distinct AI reliability conditions.
| Model | Performance | Engineering | Purpose |
|---|---|---|---|
| Reliable AI | AUC 0.861 (study subset); AUC 0.948 (full external validation) | Standard training on clean labels | Test automation bias |
| Error-Injected AI | Balanced accuracy 0.44 (sensitivity 0.40; specificity 0.47) | Systematic label poisoning via clinically plausible confounders | Test sentinel / adversarial resilience |
Primary analysis: Crossed Random-Effects GLMM (logit link)
- Random intercept for
Case_ID— controls for intrinsic image difficulty (variance 3.83 on log-odds scale) - Random intercept for
Reader_ID— controls for individual competence (variance 0.15) - Covariates: gestational age, birth weight (both non-significant: P=0.542, P=0.969)
- No session-order effects (Session 2 vs 1: OR 1.33, P=0.448)
- Post-hoc contrasts adjusted via Holm-Bonferroni
The primary GLMM identified a significant Condition × Expertise interaction for neonatologists under the Error-Injected AI condition:
| Contrast (vs Pediatric Radiologist) | OR | 95% CI | P-value |
|---|---|---|---|
| Error-Injected AI × Neonatologist | 4.16 | 1.26–13.77 | 0.020 |
Confirmed by GEE (P=0.018) and Leave-One-Neonatologist-Out sensitivity analysis (ORs 2.04–2.64 across all leave-one-out configurations).
Pediatric Radiologists maintained stable accuracy across all conditions (no significant gains or losses). Radiology Residents showed patterns consistent with automation bias.
| Group | Unaided Accuracy |
|---|---|
| Pediatric Radiologists | 90.2% |
| Radiology Residents | 85.9% |
| Neonatologists | 85.4% |
When AI was incorrect — rate at which readers accepted the wrong suggestion:
| Group | Acceptance of Incorrect AI (Reliable AI condition) |
|---|---|
| Radiology Residents | 52.0% (13/25) |
| Neonatologists | 33.3% (5/15) |
| Pediatric Radiologists | 20.0% (6/30) |
Residents vs Radiologists: P=0.016 (significant after Bonferroni correction).
When the Error-Injected AI was wrong — rate at which readers successfully overrode it:
| Group | Correct Override Rate | Wilson 95% CI |
|---|---|---|
| Neonatologists | 91.7% (66/72) | 83.0–96.0% |
| Pediatric Radiologists | 85.4% (123/144) | 78.6–90.4% |
| Radiology Residents | 81.7% (98/120) | 73.8–87.6% |
The 91.7% neonatologist override rate comes from three participating specialists (75 reader-case rows on the Error-Injected arm) and is presented as a hypothesis-generating observation that warrants prospective replication in a larger specialist cohort.
Reading time was modeled with a linear mixed-effects model on the aided set:
log(reading_time_sec) ~ disagree * reliability * group + pgy_within_5
+ (1 | reader) + (1 | case)
Headline fixed effects (REML, Satterthwaite df via lmerTest; full table in Supplementary Table 5):
| Term | β (log s) | SE | t (df) | P | Time ratio (95% CI) |
|---|---|---|---|---|---|
| Discordance (main) | 0.892 | 0.174 | 5.12 (1043.0) | <0.001 | 2.44 (1.74–3.43) |
| Discordance × Reliability[Unreliable] | -0.610 | 0.215 | -2.84 (948.6) | 0.005 | — |
| Reliability[Unreliable] (main) | 0.172 | 0.131 | 1.32 (200.9) | 0.189 | — |
Random-effect variances: σ²(reader)=0.096, σ²(case)=0.148, σ²(residual)=0.665. Marginal R²=0.101, Conditional R²=0.342 (Nakagawa–Schielzeth).
Group-specific simple slopes (disagree vs agree, marginalized over reliability):
| Group | Time ratio (disagree/agree) | 95% CI | P |
|---|---|---|---|
| Pediatric Radiologists | 1.77× | 1.44–2.18 | <0.001 |
| Neonatologists | 1.95× | 1.46–2.59 | <0.001 |
| Radiology Residents | 1.49× | 1.18–1.88 | <0.001 |
Statistical caveat (revised in round 1): the omnibus disagree × group interaction was not significant (F(2, 1096)=1.32, P=0.267) — the model does not provide evidence that the magnitude of the slowdown differs across groups. We interpret the per-group multiplicative slowdowns as evidence that AI-induced verification effort imposed a similar workflow cost across expertise levels, with the between-group differential being operationally negligible.
Note on prior reporting: an earlier draft summarized this analysis using absolute second-level differences (+1.2 / +3.1 / +4.6 s). Those raw second-level values were a technical error introduced during initial drafting and were not reproducible from the analytic dataset. They have been removed in favor of the model-adjusted multiplicative slowdowns above, which are traceable to Supplementary Table 5.
Within-session trust recalibration. The significant
Discordance × Reliability[Unreliable]interaction (β=-0.610, P=0.005) indicates that on the log-time scale, the verification cost of disagreeing with the AI was substantially attenuated under the Error-Injected condition. Once readers encountered a low-reliability AI, the cognitive cost of rejecting its output decreased — consistent with empirical recalibration of trust during the session.
The Error-Injected AI was wrong on 18 unique false-positive (FP) and 6 unique false-negative (FN) cases (336 reader-case rows across the 14 readers in the aided arm). Agreement with the wrong AI, stratified:
| Group | FP rate (n agreed / n) | FN rate (n agreed / n) | FP→FN drop |
|---|---|---|---|
| Pediatric Radiologists | 19.4% (21/108) | 0.0% (0/36) | -19.4 pp |
| Neonatologists | 11.1% (6/54) | 0.0% (0/18) | -11.1 pp |
| Radiology Residents | 18.9% (17/90) | 16.7% (5/30) | -2.2 pp |
Wilson 95% CIs and full counts in quantitative_analysis/revision_analyses/r2_8_error_type_stratification.py.
The conventional GLMM (agree_with_ai ~ group * error_type + (1|reader) + (1|case)) converged but exhibited practical separation in the FN cell (two of three groups had zero events). We therefore report Firth penalized logistic regression as the primary inferential model:
| Term | OR | 95% CI | P (Firth penalized LRT) |
|---|---|---|---|
| error_type[FN] (Ped Rad ref) | 0.06 | 0.00–0.42 | 0.001 |
| group[Radiology Resident] × error_type[FN] | 16.25 | 1.51–2239 | 0.017 |
| group[Neonatologist] × error_type[FN] | 3.62 | 0.02–721 | 0.54 |
Pediatric Radiologists and Neonatologists overrode every FN case. Residents accepted the AI's "all clear" verdict on 5/30 FN reader-case rows — the FP-to-FN drop is largely absent in trainees, suggesting that the FN cases are precisely where novice over-reliance is most clinically dangerous.
Exploratory caveat: only 6 unique FN cases are shared across all 14 readers; the Resident × FN interaction CI spans 1.5 to 2239, directionally informative but with wide uncertainty.
| Group | Usage Rate (AI-incorrect cases) | Accuracy with Map | Interpretation |
|---|---|---|---|
| Radiology Residents | 53.8% (78/145) | 78.2% (vs 73.1% without; P=0.61) | Confirmatory — reinforces over-reliance |
| Pediatric Radiologists | 34.5% (60/174) | Trending lower (81.7% vs 86.0%; P=0.58) | Intermediate |
| Neonatologists | 17.2% (15/87) | 100% (15/15; Wilson 95% CI 79.6–100%) | Refutation utility (exploratory) |
Neonatologist 100% accuracy is from 15 user-initiated map views and is presented as a descriptive observation — user-initiated access creates selection effects, and the wide Wilson CI (79.6–100%) reflects the limited subset.
Experts used explainability maps selectively to refute the AI; trainees used them indiscriminately, often reinforcing over-reliance.
"Ultimately, in neonatal pneumoperitoneum, AI reliability affects clinicians through verification behavior and error phenotypes rather than accuracy alone. Highly reliable AI tends to induce automation bias in trainees, whereas intentionally error-injected AI can trigger vigilance in experts. Future evaluation and deployment frameworks must explicitly measure expertise-dependent behaviors to ensure resilience in time-critical emergencies."
- Simulated environment — Cannot fully replicate the time pressures of a live NICU
- Small neonatologist cohort (n=3) — Mitigated by 375 independent decision points for the subgroup and LONO sensitivity analysis
- Saliency map analysis is exploratory — User-initiated access creates selection effects; randomized exposure required for causal inference
- Generalizability — Replication in larger, multicenter specialist cohorts needed
- Source code (preprocessing, model, training, evaluation, saliency, statistical analysis): github.com/junjslee/neonatal-ai-reliability
- Educational sandbox: neonatal-ai-sandbox.pages.dev
- Primary statistical pipeline:
quantitative_analysis/reader_study_full_analysis.py— GLMM crossed random effects, GEE sensitivity, time/CAM mechanism analyses, HCI-type stacked bars (Type 1–4 derivation including the Type 4 automation-bias and Type 3 sentinel-override counts that underlie §3–§4). - Revision-round analyses:
quantitative_analysis/revision_analyses/— R2-6 (reading-time LMM full output), R2-7 (between-group differential omnibus + simple slopes), R2-8 (FP-vs-FN error-type stratification with Firth sensitivity). - Model checkpoints: Both the Reliable AI and Error-Injected AI weights are included in this repository under
quantitative_analysis/standalone_model_performance/rad_dino/. These are the exact checkpoints used in the reader study and can be used to reproduce inference results without retraining. Weights are derived from microsoft/rad-dino (MIT License, research use only — not for clinical practice). - Raw image data: Cannot be publicly redistributed (IRB/licensing); external validation set available via AI-Hub
- De-identified derived data (reader metrics, AI predictions, consensus labels): Available upon request to corresponding authors
If you use the code, findings, or the error-injection validation framework, please cite:
Lee, J., Kim, Y., Kim, V., Park, C., Song, J. M., Kwon, J., Nam, Y., Lenehan, P., Kim, D. Y., Cho, Y. A., Kim, P. H., Hwang, J.-Y., Lee, J., Lee, B. S., Jung, E., Jung, A. Y., Choi, J., Kim, N.* & Yoon, H. M.* Expertise modulates automation bias and sentinel behavior in human-AI collaborative diagnosis of neonatal pneumoperitoneum. npj Digit. Med. (in revision, 2026).
*Co-corresponding authors: Namkug Kim, PhD (namkugkim@gmail.com); Hee Mang Yoon, MD, PhD (espoirhm@gmail.com).
Machine-readable metadata: see CITATION.cff. A final BibTeX entry will be added on acceptance.
- Namkug Kim, PhD — namkugkim@gmail.com (MI2RL, Asan Medical Center)
- Hee Mang Yoon, MD, PhD — espoirhm@gmail.com (Massachusetts General Hospital / Asan Medical Center)

