159 changes: 159 additions & 0 deletions repeater/sensors/lafvin_ups_3s.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,159 @@
"""
LAFVIN UPS Module 3S battery monitor plug-in — INA219 at I2C 0x41.

Reads a 3S lithium-ion/LiPo battery pack via INA219. Reports pack voltage,
current, power, estimated state-of-charge, and charge state.

The INA219 address is 0x41 by default (A0 bridged to VCC, A1 to GND on the
LAFVIN board) but is configurable for boards wired differently.

Requires: pip install smbus2

Config example:
- type: lafvin_ups_3s
name: "battery"
enabled: true
auto_install_packages: false
settings:
i2c_address: 0x41 # Default LAFVIN UPS 3S address
bus_number: 1 # I2C bus (1 for Raspberry Pi default)
shunt_ohms: 0.1 # Shunt resistor value in ohms
max_amps: 5.0 # Maximum expected current in amps
"""

from __future__ import annotations

import time
from typing import Any, Dict, Optional

from .base import SensorBase
from .registry import SensorRegistry

# INA219 register addresses
_REG_CONFIG = 0x00
_REG_SHUNT = 0x01
_REG_BUS = 0x02
_REG_POWER = 0x03
_REG_CURRENT = 0x04
_REG_CALIBRATION = 0x05

# 32V range, ±320mV shunt gain, 12-bit ADC, continuous shunt+bus
_CONFIG_VALUE = 0x399F

# 3S LiPo/Li-ion pack voltage thresholds (3 cells in series)
_V_MAX = 12.6 # 4.20 V/cell × 3 — fully charged
_V_MIN = 9.0 # 3.00 V/cell × 3 — cutoff


def _pack_voltage_to_percent(v: float) -> int:
"""Piecewise linear SoC estimate for a 3S Li-ion/LiPo pack (9.0–12.6 V)."""
cell = v / 3.0
if cell >= 4.20: return 100
if cell >= 4.00: return int(85 + (cell - 4.00) / 0.20 * 15)
if cell >= 3.80: return int(60 + (cell - 3.80) / 0.20 * 25)
if cell >= 3.70: return int(40 + (cell - 3.70) / 0.10 * 20)
if cell >= 3.50: return int(15 + (cell - 3.50) / 0.20 * 25)
if cell >= 3.00: return int( (cell - 3.00) / 0.50 * 15)
return 0


@SensorRegistry.register("lafvin_ups_3s")
class LafvinUps3sSensor(SensorBase):
sensor_type = "lafvin_ups_3s"

def __init__(self, name: str, config: Optional[Dict[str, Any]] = None, log=None):
super().__init__(name=name, config=config, log=log)

addr = self.settings.get("i2c_address", 0x41)
self.i2c_address = int(addr, 0) if isinstance(addr, str) else int(addr)
self.bus_number = int(self.settings.get("bus_number", 1))
self.shunt_ohms = float(self.settings.get("shunt_ohms", 0.1))
self.max_amps = float(self.settings.get("max_amps", 5.0))

# INA219 calibration per datasheet
self.current_lsb = self.max_amps / 32768.0
cal = int(0.04096 / (self.current_lsb * self.shunt_ohms))
self.calibration = max(1, min(cal, 0xFFFF))
self.power_lsb = self.current_lsb * 20.0

self.available = False

if not self.ensure_python_modules([("smbus2", "smbus2")]):
return

try:
import smbus2 # type: ignore[import-not-found]
self._smbus2 = smbus2

bus = smbus2.SMBus(self.bus_number)
try:
self._write(bus, _REG_CONFIG, _CONFIG_VALUE)
self._write(bus, _REG_CALIBRATION, self.calibration)
time.sleep(0.15)
finally:
bus.close()

self.available = True
self.log.info(
"LAFVIN UPS 3S INA219 initialized (addr=0x%02X, bus=%d, shunt=%.3fΩ)",
self.i2c_address,
self.bus_number,
self.shunt_ohms,
)
except Exception as exc:
self.log.warning(
"LAFVIN UPS 3S init failed (addr=0x%02X, bus=%d): %s",
self.i2c_address,
self.bus_number,
exc,
)

def _write(self, bus, reg: int, val: int) -> None:
bus.write_i2c_block_data(
self.i2c_address, reg, [(val >> 8) & 0xFF, val & 0xFF]
)

def _read_u(self, bus, reg: int) -> int:
d = bus.read_i2c_block_data(self.i2c_address, reg, 2)
return (d[0] << 8) | d[1]

def _read_s(self, bus, reg: int) -> int:
v = self._read_u(bus, reg)
return v - 0x10000 if v & 0x8000 else v

def _read(self) -> Dict[str, Any]:
"""Read voltage, current, power, and derived battery state."""
if not self.available:
raise RuntimeError("LAFVIN UPS 3S not available")

try:
bus = self._smbus2.SMBus(self.bus_number)
try:
self._write(bus, _REG_CALIBRATION, self.calibration)

bus_v = (self._read_u(bus, _REG_BUS) >> 3) * 4 / 1000.0
shunt_mv = self._read_s(bus, _REG_SHUNT) * 0.01
current_ma = self._read_s(bus, _REG_CURRENT) * self.current_lsb * 1000.0
power_mw = self._read_u(bus, _REG_POWER) * self.power_lsb * 1000.0
finally:
bus.close()

pct = _pack_voltage_to_percent(bus_v)

if current_ma < -50:
state = "charging"
elif current_ma > 50:
state = "discharging"
else:
state = "idle"

return {
"bus_voltage_v": round(bus_v, 3),
"shunt_voltage_mv": round(shunt_mv, 2),
"current_ma": round(current_ma, 1),
"power_mw": round(power_mw, 1),
"battery_percent": pct,
"charge_state": state,
}
except Exception as exc:
raise RuntimeError(f"LAFVIN UPS 3S read failed: {exc}") from exc