43 changes: 42 additions & 1 deletion quam_builder/architecture/quantum_dots/components/xy_drive.py
Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,7 @@
from quam.core import quam_dataclass
from quam.components import MWChannel, pulses
from quam.components.channels import IQChannel, MWChannel, SingleChannel
from qm.qua import align

from quam_builder.tools.power_tools import (
calculate_voltage_scaling_factor,
Expand Down Expand Up @@ -50,7 +51,7 @@ def calculate_voltage_scaling_factor(
return calculate_voltage_scaling_factor(fixed_power_dBm, target_power_dBm)


__all__ = ["XYDriveBase", "XYDriveSingle", "XYDriveIQ", "XYDriveMW"]
__all__ = ["XYDriveBase", "XYDriveSingle", "XYDriveIQ", "XYDriveMW", "XYDriveDualMW"]


@quam_dataclass
Expand Down Expand Up @@ -195,3 +196,43 @@ def set_output_power(
def add_pulse(self, name: str, pulse: pulses.Pulse) -> None:
"""Add or update a pulse in the drive operations"""
self.operations[name] = pulse

@quam_dataclass
class XYDriveDualMW(XYDriveMW, XYDriveBase):
"""
Combine 2 MW FEM ports using an external mixer to be able to reach frequencies of up to 21GHz.

This subclass will be designated to the IF. The LO will be a MWChannel held as an attribute of this class.
The idea is that we set the LO & forget it. That way, any subsequent play function (via the macro) will use this
play command, which plays both a constant LO tone and an enveloped IF to the external mixer.
"""
opx_output_LO: MWChannel
default_LO_frequency = 10e9

def __post_init__(self):
self.opx_output_LO.intermediate_frequency = 0

# How and what do we define the length to be here? Open to ideas
if "cw" not in self.opx_output_LO.operations:
self.opx_output_LO.operations["cw"] = pulses.SquarePulse(amplitude = 0.1, length = 1000)

@property
def upconverter_frequency(self):
"""Returns the up-converter/LO frequency in Hz."""
return self.opx_output.upconverter_frequency + self.opx_output_LO.upconverter_frequency

def play(
self,
pulse_name: str,
**kwargs,
):
duration = kwargs.get("duration")
if duration is None:
lo_duration = self.operations[pulse_name].length // 4
else:
lo_duration = duration

align(self.name, self.opx_output_LO.name)
self.opx_output_LO.play("cw", duration=lo_duration)
super().play(pulse_name, **kwargs)
align(self.name, self.opx_output_LO.name)
Loading