reproducr-cmc reproducr website

reproducibility R-CMD-check

End-to-end reproducr pipeline for a simulated CMC statistical package — dissolution f2, ICH Q1E stability shelf-life, and ICH Q2(R1) assay method validation. renv environment locking, pharma-style QC report.

Domain Chemistry, Manufacturing and Controls (CMC)
Analyses Dissolution f2, stability, assay method validation
Regulatory framework ICH Q1B, ICH Q1E, ICH Q2(R1)
Environment renv — locked environment
Report style pharma
Outputs certified 20
Audience CMC statisticians, analytical chemists, regulatory affairs

See the full walkthrough: DEMO.md


Study overview

A simulated CMC statistical package for an immediate-release tablet formulation, covering three standard regulatory analyses:

1. Dissolution profile comparison (ICH Q1B / Q4B Annex 7)

  • f2 similarity factor comparing reference and test dissolution profiles
  • 6 time points (15–90 min), 12 vessels per arm
  • Bootstrap 90% CI for f2
  • Acceptance: f2 ≥ 50

2. Stability analysis (ICH Q1E)

  • Linear regression of assay (% label claim) vs time
  • Three storage conditions: LTS (25°C/60%RH), INT (30°C/65%RH), ACC (40°C/75%RH)
  • Shelf-life estimated where 95% one-sided LCL crosses 90% LC acceptance limit

3. Assay method validation (ICH Q2(R1))

  • Linearity: 5 concentration levels (50–150%), R² ≥ 0.999
  • Repeatability: 6 replicates at 100%, CV ≤ 2%
  • Intermediate precision: mixed model (nlme), CV ≤ 3%
  • Accuracy: % recovery at 80%, 100%, 120% levels (98–102%)

Key results (simulated data)

Dissolution:

Metric Value Acceptance
f2 similarity factor ≥ 50
f2 90% CI (bootstrap)

Stability slopes (%LC/month):

Condition Slope 95% LCL
LTS (25°C/60%RH)
INT (30°C/65%RH)
ACC (40°C/75%RH)

Method validation:

Test Result Acceptance
Linearity R² ≥ 0.999
Repeatability CV ≤ 2%
Intermediate precision CV ≤ 3%

Results populated by CI on each run — see .reproducr.rds for certified values.


Why CMC analyses need reproducibility tooling

CMC analyses feed directly into regulatory submissions (CTD Module 3 / NDA / ANDA). Silent breaking changes in statistical packages are especially consequential here because:

  1. Regulatory precedent — results in a submission are compared against reanalysis during review. Any numerical difference requires explanation.

  2. Long timelines — a stability programme may span 5 years from IND to NDA. Package upgrades over that period are inevitable.

  3. Method transfers — the same analysis may be run at multiple sites (lab, CRO, sponsor). Locale differences and package version differences can produce different shelf-life estimates.

  4. nlme sensitivitylme() optimizer tolerance and default REML settings have changed across versions. Intermediate precision estimates are sensitive to these changes.

reproducr flags these risks at the call level and certifies the outputs so any numerical change between runs is immediately visible.


Running locally

# Clone the repo, then:
renv::restore()
source("analysis.R")

library(reproducr)
report <- audit_script("analysis.R", renv = TRUE)
risks  <- risk_score(report)
print(risks)

CI/CD

Workflow Purpose
R-CMD-check.yml Restore renv, run structural tests
reproducr-audit.yml Audit, certify, detect drift, update badge

Part of the reproducr gallery

Example Domain renv Report style
reproducr-ecology Ecology / penguins No minimal
reproducr-clinical Clinical trials / oncology Yes pharma
reproducr-rwe Real world evidence Yes academic
reproducr-cmc (this repo) CMC statistics Yes pharma